Saltar para:
Logótipo
Você está em: Início » Publicações » Visualização » Automatic Segmentation of the Optic Nerve Head Region in Optical Coherence Tomography: A Methodological Review

Automatic Segmentation of the Optic Nerve Head Region in Optical Coherence Tomography: A Methodological Review

Título
Automatic Segmentation of the Optic Nerve Head Region in Optical Coherence Tomography: A Methodological Review
Tipo
Outra Publicação em Revista Científica Internacional
Ano
2022
Autores
Marques, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
De Jesus, DA
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Barbosa-Breda, J
(Autor)
FMUP
Van Eijgen, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Stalmans, I
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
van Walsum, T
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Klein, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Vaz, PG
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Brea, LS
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 220
ISSN: 0169-2607
Editora: Elsevier
Outras Informações
ID Authenticus: P-00W-J3S
Abstract (EN): The optic nerve head (ONH) represents the intraocular section of the optic nerve, which is prone to damage by intraocular pressure (IOP). The advent of optical coherence tomography (OCT) has enabled the evaluation of novel ONH parameters, namely the depth and curvature of the lamina cribrosa (LC). Together with the Bruch's membrane minimum-rim-width (BMO-MRW), these seem to be promising ONH parameters for diagnosis and monitoring of retinal diseases such as glaucoma. Nonetheless, these OCT derived biomarkers are mostly extracted through manual segmentation, which is time-consuming and prone to bias, thus limiting their usability in clinical practice. The automatic segmentation of ONH in OCT scans could further improve the current clinical management of glaucoma and other diseases. This review summarizes the current state-of-the-art in automatic segmentation of the ONH in OCT. PubMed and Scopus were used to perform a systematic review. Additional works from other databases (IEEE, Google Scholar and ARVO IOVS) were also included, resulting in a total of 29 reviewed studies. For each algorithm, the methods, the size and type of dataset used for validation, and the respective results were carefully analysed. The results show a lack of consensus regarding the definition of segmented regions, extracted parameters and validation approaches, highlighting the importance and need of standardized methodologies for ONH segmentation. Only with a concrete set of guidelines, these automatic segmentation algorithms will build trust in data-driven segmentation models and be able to enter clinical practice. (c) 2022 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ )
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 13
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Skin Lesion Computational Diagnosis of Dermoscopic Images: Ensemble Models based on Input Feature Manipulation (2017)
Artigo em Revista Científica Internacional
Roberta B. Oliveira; Aledir S. Pereira; João Manuel R. S. Tavares
Segmentation of ultrasound images of the carotid using RANSAC and cubic splines (2011)
Artigo em Revista Científica Internacional
Rui Rocha; Aurélio Campilho; Jorge A. Silva; Elsa Azevedo; Rosa Santos
Red blood cells tracking and cell-free layer formation in a microchannel with hyperbolic contraction: A CFD model validation (2022)
Artigo em Revista Científica Internacional
Gracka, M; Lima, R; Miranda, JM; Student, S; Melka, B; Ostrowski, Z
Positive state observer for the automatic control of the depth of anesthesia-Clinical results (2019)
Artigo em Revista Científica Internacional
Filipa N. Nogueira; T. Mendonça; Maria Paula Rocha

Ver todas (29)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Medicina da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Página gerada em: 2024-11-05 às 05:51:02
Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias | Política de Captação e Difusão da Imagem Pessoal em Suporte Digital