Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > A Reflectance Flow-through Thionine Sol-gel Sensor for the Determination of Se(IV)

A Reflectance Flow-through Thionine Sol-gel Sensor for the Determination of Se(IV)

Título
A Reflectance Flow-through Thionine Sol-gel Sensor for the Determination of Se(IV)
Tipo
Artigo em Revista Científica Internacional
Ano
2010
Autores
Carvalhido, JAE
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Araujo, AN
(Autor)
FFUP
Montenegro, MCBSM
(Autor)
FFUP
Revista
Título: Analytical SciencesImportada do Authenticus Pesquisar Publicações da Revista
Vol. 26 6
Páginas: 665-669
ISSN: 0910-6340
Indexação
Publicação em ISI Web of Science ISI Web of Science
Pubmed / Medline
Classificação Científica
FOS: Ciências médicas e da saúde > Outras ciências médicas
CORDIS: Ciências da Saúde
Outras Informações
ID Authenticus: P-003-5TJ
Resumo (PT): In this work, a reversible sensor to assess the total Se(IV) content in samples is described. Pre-activated glass slides were spin-coated with 100 μL of a 20-h aged sol-gel mixture of 1 mL of tetramethoxysilane, 305 μL of 50 mmol L−1 HCl and 2.0 mg of thonine. The flow-cell consisted of one of those slides as a window, and was filled with beads of a polystyrene anionic exchange resin to retain Se(IV) in the form of selenite ions. A reflectance transduction scheme at a wavelength of 596 nm was adopted. The cell was coupled to a multicommutation flow system where a programmed volume of a sample solution and 373 μL of 0.4 mmol L−1 iodide in a 1.6 mol L−1 HCl solution were sequentially inserted into the cell. The iodine produced from the reaction of retained Se(IV) with iodide bleached the blue color of thionine. Considering a sample volume of 2.30 mL, with which the preconcentration step was minimized, a linear dynamic working range between 1.5 to 20 μg mL−1 and a detection limit of 0.29 μg mL−1 were obtained. The sensor enabled us to perform approximately 200 assays, and provided results similar to those of electrothermal atomic absorption spectrometry. <br> <br> <a target="_blank" href="http://www.jstage.jst.go.jp/article/analsci/26/6/26_665/_article"> Texto integral </a> <br> <br>
Abstract (EN): In this work, a reversible sensor to assess the total Se(W) content in samples is described. Pre-activated glass slides were spin-coated with 100 mu L of a 20-h aged sol-gel mixture of 1 mL of tetramethoxysilane, 305 mu L of 50 mmol L(-1) HCl and 2.0 mg of thonine. The flow-cell consisted of one of those slides as a window, and was filled with beads of a polystyrene anionic exchange resin to retain Se(IV) in the form of selenite ions. A reflectance transduction scheme at a wavelength of 596 nm was adopted. The cell was coupled to a multicommutation flow system where a programmed volume of a sample solution and 373 mu L of 0.4 mmol L(-1) iodide in a 1.6 mol L(-1) HCl solution were sequentially inserted into the cell. The iodine produced from the reaction of retained Se(IV) with iodide bleached the blue color of thionine. Considering a sample volume of 2.30 mL, with which the preconcentration step was minimized, a linear dynamic working range between 1.5 to 20 mu L mL(-1) and a detection limit of 0.29 mu L mL(-1) were obtained. The sensor enabled us to perform approximately 200 assays, and provided results similar to those of electrothermal atomic absorption spectrometry.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Contacto: anaraujo@ff.up.pt
Nº de páginas: 5
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Oxidoreductase Behavior in Ionic Liquids: a Review (2008)
Outra Publicação em Revista Científica Internacional
Paula C A G Pinto; Lucia L M F S Saraiva; Jose L F C Lima
Multisyringe flow injection analysis: State-of-the-art and perspectives (2006)
Outra Publicação em Revista Científica Internacional
Segundo, MA; Magalhaes, LM
Simultaneous determination of tocopherols and tocotrienols in hazelnuts by a normal phase liquid chromatographic method (2005)
Artigo em Revista Científica Internacional
Joana S AMARAL; Susana Casal; Duarte TORRES; Rosa M SEABRA; Beatriz P P OLIVEIRA
Simultaneous determination of potassium and nitrate ions in mouthwashes using sequential injection analysis with potentiometric detection (2008)
Artigo em Revista Científica Internacional
Zarate, N; Irazu, E; Araujo, AN; Montenegro, MCBSM; Perez Olmos, R

Ver todas (35)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Reitoria da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Página gerada em: 2024-09-19 às 05:42:24 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias