Go to:
Logótipo
Você está em: Start » Publications » View » Microcystin-LR detection in water by the Fabry-Perot interferometer using an optical fibre coated with a sol-gel imprinted sensing membrane
Publication

Microcystin-LR detection in water by the Fabry-Perot interferometer using an optical fibre coated with a sol-gel imprinted sensing membrane

Title
Microcystin-LR detection in water by the Fabry-Perot interferometer using an optical fibre coated with a sol-gel imprinted sensing membrane
Type
Article in International Scientific Journal
Year
2011
Authors
Raquel B Queiros
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Silva, SO
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Noronha, JP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Frazao, O
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Jorge, P
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Aguilar, G
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Marques, PVS
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Sales, MGF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Journal
Vol. 26 No. 4
Pages: 3932-3937
ISSN: 0956-5663
Publisher: Elsevier
Scientific classification
FOS: Engineering and technology > Nano-technology
Other information
Authenticus ID: P-002-RF9
Abstract (EN): Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 mu g L(-1) of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry-Perot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol-gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol-gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry-Perot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3-1.4 mu g L(-1) with a sensitivity of -12.4 +/- 0.7 nm L mu g(-1). The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of -5.9 +/- 0.2 nm L mu g(-1). The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.
Language: English
Type (Professor's evaluation): Scientific
Contact: mgf@isep.ipp.pt
No. of pages: 6
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same scientific areas

Small Precise Pointing Device Utilizing Impact Force Accompanying Quick Deformation of Piezo-Electric Element (1999)
Patent
Higuchi Toshiro; Arvid Bergander; Yamagata Yutaka; Joaquim Gabriel Magalhães Mendes; Riyuu Eiden
Synthesis of poluurethane-urea microcapsules with perfume for textile application (2009)
Poster in an International Conference
Sofia N. Rodrigues; Isabel Martins; Maria Barreiro; V. G. Mata; Alírio E. Rodrigues
Evaluation of surfactants of thyme oil microcapsules prepared by coacervation (2010)
Poster in an International Conference
Isabel Martins; Sofia N. Rodrigues; Maria Barreiro; Alírio E. Rodrigues
Towards a reliable technology for antioxidant capacity and oxidative damage evaluation: Electrochemical (bio)sensors (2011)
Another Publication in an International Scientific Journal
Fatima Barroso, MF; de los Santos Alvarez, N; Delerue Matos, C; Oliveira, MBPP

See all (86)

Of the same journal

3D biosensors in advanced medical diagnostics of high mortality diseases (2019)
Another Publication in an International Scientific Journal
Rebelo, R; Barbosa, AI; Caballero, D; Kwon, IK; Oliveira, JM; Kundu, SC; Rui Reis; Correlo, VM
Towards a reliable technology for antioxidant capacity and oxidative damage evaluation: Electrochemical (bio)sensors (2011)
Another Publication in an International Scientific Journal
Fatima Barroso, MF; de los Santos Alvarez, N; Delerue Matos, C; Oliveira, MBPP
Electrochemical biosensors for Salmonella: State of the art and challenges in food safety assessment (2018)
Another Publication in an International Scientific Journal
Silva, NFD; Magalhaes, JMCS; Cristina Freire; Delerue Matos, C
Comparative analysis of electrochemical and optical sensors for detection of chronic wounds biomarkers: A review (2024)
Another Publication in an International Scientific Journal
Mota, FAR; Passos, MLC; Santos, JLM; Lucia L M F S Saraiva
Thin and flexible bio-batteries made of electrospun cellulose-based membranes (2011)
Article in International Scientific Journal
Baptista, AC; José Inácio Martins; Fortunato, E; Martins, R; Borges, JP; Ferreira, I

See all (30)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Medicina da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-10-05 at 05:24:42
Acceptable Use Policy | Data Protection Policy | Complaint Portal | Política de Captação e Difusão da Imagem Pessoal em Suporte Digital