Go to:
Logótipo
Você está em: Start » Publications » View » Impact of atmospherical stability and intra-hour variation of meteorological data in the variability of building air change rates
Publication

Impact of atmospherical stability and intra-hour variation of meteorological data in the variability of building air change rates

Title
Impact of atmospherical stability and intra-hour variation of meteorological data in the variability of building air change rates
Type
Article in International Scientific Journal
Year
2022
Authors
Vitor E. M. Cardoso
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Maria de Lurdes Simões
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Nuno Ramos
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Ricardo M. S. F. Almeida
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Manuela Almeida
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lígia Conceição
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 207
Pages: 1-13
ISSN: 0360-1323
Publisher: Elsevier
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-00V-M2G
Resumo (PT):
Abstract (EN): In contrast with structural engineering, where the focus for design is on extreme values, for the proper assessment and modelling of air change rates in natural ventilation and infiltration, one must use the full range of input variables. Most of the modelling in infiltration research relies on hourly datasets for air infiltration balance. This consideration overlooks the intra-hour variability on meteorological variables. Additionally, it is customary to assume unchanging neutral atmospheric conditions when modelling, which affects the calculated airflows. This work intends to detail and quantify these effects in a case study representative of an average single-family dwelling in a Southern European climate setup. By comparing four setups with an increasing degree of complexity, a median of 0.04 h(-1) of the hourly standard deviations in air change rates (ACH) is attributed to the time step effect. Approximately 43% of the occurrences experienced non-neutral atmospheric stability, skewing for stable conditions. This effect contributed to differences in the ACHs ranging from-0.202 to 0.131 h(-1)& nbsp;at the 5% and 95% quantiles. Overall, by using hourly uniform distributions and smart sampling of meteorological variables, one ensures that the values in between and others potentially occurring around the boundaries are being considered for air change rates calculation, and therefore providing a more detailed picture of actual conditions.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 13
Documents
We could not find any documents associated to the publication with allowed access.
Related Publications

Of the same journal

Residential buildings airtightness frameworks: A review on the main databases and setups in Europe and North America (2020)
Another Publication in an International Scientific Journal
Poza Casado, I; Cardoso, VEM; Almeida, RMSF; Meiss, A; Nuno Ramos; Padilla Marcos, MA
User Influence Upon Building Indoor Humidity (1989)
Article in International Scientific Journal
Vitor Abrantes Almeida; Vasco Freitas
Treatment of rising damp in historical buildings: wall base ventilation (2007)
Article in International Scientific Journal
M. Isabel M. Torres; Vasco Peixoto de Freitas
Thermal comfort evaluation in cruise terminals (2017)
Article in International Scientific Journal
Vitor Cardoso; Nuno M. M. Ramos; Ricardo M. S. F. Almeida; Eva Barreira; João Poças Martins; Maria de Lurdes Simões; Luís Sanhudo; Bruno Ribeiro
the role of the PASSYS test cell in the modelling and integrated simulation of an innovative window (2008)
Article in International Scientific Journal
Vítor Leal; Eduardo Maldonado

See all (25)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Medicina da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-10-03 at 12:40:08
Acceptable Use Policy | Data Protection Policy | Complaint Portal | Política de Captação e Difusão da Imagem Pessoal em Suporte Digital