Go to:
Logótipo
Você está em: Start » Publications » View » Model and Experimental Characteristics of a Pneumatic Linear Peristaltic Actuator
Publication

Model and Experimental Characteristics of a Pneumatic Linear Peristaltic Actuator

Title
Model and Experimental Characteristics of a Pneumatic Linear Peristaltic Actuator
Type
Article in International Scientific Journal
Year
2020
Authors
João Pedro Falcão Carneiro
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Pinto, JB
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fernando Gomes Almeida
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Fateri, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 11
Final page: 76
ISSN: 2078-2489
Publisher: MDPI
Indexing
Other information
Authenticus ID: P-00R-VJS
Abstract (EN): Pneumatic linear peristaltic actuators present several potential advantages over conventional ones such as low cost, virtually unlimited stroke, and an easy implementation of curved motion profiles. However, the body of this type of actuators also suffers from high mechanical stress, leading to a decrease in the hose wall thickness, which leads to increased leakages between chambers. One way to potentially minimize this problem is to impose the force instead of the displacement between rollers. This paper describes the model and experimental characteristics of a new prototype of a linear pneumatic peristaltic actuator where either the force or the displacement between rollers can be imposed. Namely, experimental friction characteristics and the leakage between chambers are determined in the configuration where the force between rollers is imposed. Lastly, a third-order linear model is experimentally identified. Therefore, this study establishes the basis for future research focused on the service life and leakage obtained whenever the force between rollers is imposed.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 13
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Teaching Software Engineering Topics Through Pedagogical Game Design Patterns: An Empirical Study (2020)
Article in International Scientific Journal
Nuno Flores; Paiva, ACR; Cruz, N
Screening System for Cardiac Problems through Non-Invasive Identification of Blood Pressure Waveform (2020)
Article in International Scientific Journal
Paulo Abreu; Fernando Carneiro; Maria Teresa Restivo
Robust Complaint Processing in Portuguese (2021)
Article in International Scientific Journal
Henrique Lopes Cardoso; Osorio, TF; Barbosa, LV; Rocha, G; reis, lp; Machado, JP; Oliveira, AM
Recognizing textual entailment: Challenges in the Portuguese language (2018)
Article in International Scientific Journal
Gil Rocha; Henrique Lopes Cardoso
Prototype to Increase Crosswalk Safety by Integrating Computer Vision with ITS-G5 Technologies (2020)
Article in International Scientific Journal
Gaspar, F; Guerreiro, V; Loureiro, P; Costa, P; Mendes, S; Rabadao, C

See all (16)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Medicina da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-11-05 at 15:31:55
Acceptable Use Policy | Data Protection Policy | Complaint Portal | Política de Captação e Difusão da Imagem Pessoal em Suporte Digital