Você está em: Start » Publications » View » Sensing characteristics of tapered High-Birefringent optical fiber
Publication

Sensing characteristics of tapered High-Birefringent optical fiber

Title
Sensing characteristics of tapered High-Birefringent optical fiber
Type
Article in International Conference Proceedings Book
Year
2012
Authors
Layeghi, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Zibaii, MI
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sadeghi, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Frazao, O
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Jorge, PAS
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Latifi, H
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
22nd International Conference on Optical Fiber Sensors (OFS)
Beijing, PEOPLES R CHINA, OCT 15-19, 2012
Other information
Authenticus ID: P-008-A4C
Abstract (EN): A high-birefringent fiber (HBF) was tapered as adiabatic in sequence steps by utilizing a CO2 laser and its birefringence was measured in fiber loop mirror (FLM) setup. The birefringence of tapered section and total sensor was obtained to be -8.02x10(-2), and 2.46x10(-4), respectively. Then, refractive index (RI) sensitivity increased and temperature sensitivity of the tapered Hi-Bi fiber (THBF) decreased. The sensitivity of the proposed FLM interferometer for RI changes in the range from 1.3380 to 1.3470 was measured to be 389.85 nm/RIU. The temperature sensitivity in the range from 50 degrees C to 90 degrees C was measured to be -1.19nm/degrees C.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2024 © Faculdade de Medicina da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-09-28 at 08:26:09
Acceptable Use Policy | Data Protection Policy | Complaint Portal | Política de Captação e Difusão da Imagem Pessoal em Suporte Digital