Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment

Título
Ozone membrane contactor for tertiary treatment of urban wastewater: Chemical, microbial and toxicological assessment
Tipo
Artigo em Revista Científica Internacional
Ano
2023
Autores
Presumido, PH
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ribeirinho-Soares, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Montes, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Quintana, JB
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Rodil, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ribeiro, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Neuparth, T
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Santos, MM
(Autor)
FCUP
Feliciano, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Olga C Nunes
(Autor)
FEUP
Gomes, AI
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Vitor Vilar
(Autor)
FEUP
Revista
Vol. 892
ISSN: 0048-9697
Editora: Elsevier
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citações
Outras Informações
ID Authenticus: P-00Y-HRR
Abstract (EN): A membrane ozone contactor, operated under continuous mode, was applied to promote the tertiary treatment of urban wastewater (UWW), targeting the removal of contaminants of emerging concern (CECs), bacterial disinfection, and toxicity reduction. This system relies on the homogeneous radial distribution of ozone (O3) in the reaction zone by titration through a microfiltration borosilicate tubular membrane, while the UWW swirls around the membrane and drags the O3 microbubbles generated in the membrane shell-side. The membrane is coated with titanium dioxide (TiO2-P25) and radiation can be externally supplied via four UV lamps. The ozonation tests were carried out with secondary-treated UWW collected in different seasons (winter and summer) and spiked with a mix of 19 CECs (10 & mu;g L-1 each). For an O3 dose of 18 g m-3, the best performance was obtained by increasing the O3 concentration (maximum [O3]G,inlet of 200 g Nm-3) and decreasing the gas flow rate (minimum QG of 0.15 Ndm3 min-1), providing the highest ozone transfer yield (88 %) and, thus higher specific ozone dose (g O3 per g dissolved organic carbon). Under these conditions, removals >80 % or concentrations below the limit of quantification were obtained for up to 13 of the 19 CECs and reductions up to 5 log units for total heterotrophs and below the limit of detection for enterobacteria and enterococci. Tests including a UVC dose of 0.10 kJ L-1 enhanced disinfection ability but had no impact on CECs oxidation. After ozonation, the abundance of antibiotic resistant bacteria was reduced but not elimi-nated , microbial regrowth after 3-day storage was observed. No toxic effect was detected on zebrafish embryos using a dilution factor of 4 for the ozonized UWW , when granular activated carbon adsorption was subsequently applied the dilution factor decreased to 2.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 14
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

The prediction of PAHs bioavailability in soils using chemical methods: State of the art and future challenges (2014)
Outra Publicação em Revista Científica Internacional
Cachada, A; Pereira, R; Ferreira da Silva, EF; Duarte, AC
The last frontier: Coupling technological developments with scientific challenges to improve hazard assessment of deep-sea mining (2018)
Outra Publicação em Revista Científica Internacional
Santos, MM; Jorge, PAS; Coimbra, J; Vale, C; Caetano, M; Bastos, L; Iglesias, I; Guimarães, L; Reis Henriques, MA; Luis Oliva Teles; Vieira, MN; Raimundo, J; Pinheiro, M; Nogueira, V; Pereira, R; Neuparth, T; Ribeiro, MC; E. Pereira da Silva; Castro, LFC
Tannin-based coagulants: Current development and prospects on synthesis and uses (2022)
Outra Publicação em Revista Científica Internacional
Tomasi, IT; Machado, CA; Boaventura, RAR; Cidália Botelho; Santos, SCR
Risk assessment of urban soils contamination: The particular case of polycyclic aromatic hydrocarbons (2016)
Outra Publicação em Revista Científica Internacional
Cachada, A; Ferreira da Silva, EF; Duarte, AC; Ruth Pereira
Reconciling agriculture and stream restoration in Europe: A review relating to the EU Water Framework Directive (2017)
Outra Publicação em Revista Científica Internacional