Relationship of design features of stemmed tibial knee prosthesis with stress shielding and end-of-stem pain

Título
Relationship of design features of stemmed tibial knee prosthesis with stress shielding and end-of-stem pain
Tipo
Artigo em Revista Científica Internacional
Ano
2009
Autores
A. Completo
(Autor)
FEUP
P. Talaia
(Autor)
FEUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
F. Fonseca
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
J. A. Simões
(Autor)
FEUP
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Título: Materials and DesignImportada do Authenticus Pesquisar Publicações da Revista
Vol. 30 4
Páginas: 1391-1397
ISSN: 0261-3069
Editora: Elsevier Science
Indexação
Publicação em ISI Web of Science ISI Web of Science
Publicação em Scopus Scopus
Classificação Científica
FOS: Ciências da engenharia e tecnologias > Engenharia mecânica
Outras Informações
Abstract (EN): Materials and design are important issues within general product development and even more in biomedical product. Knee prosthesis is a product that still lacks of adequate design solutions. Stress shielding and stress concentrations related to the end-of-stem pain are frequent clinical evidences that are intimately related to the design of the prosthesis and stems used in revision total knee arthroplasty, to the femoral and tibial components. Stress shielding and stress concentrations were assessed through finite element analyses of different tibial stem designs. Stress shielding was determined considering the relative minimal principal cancellous bone stresses between implanted and intact tibiae models. Scintigraphy and radiographs of painful implanted knees were assessed to correlate clinical findings with the finite element stresses. This study showed that stem design, geometry and material change the mechanical behavior of bone around tibial tray and stem in revision TKA. For the analyzed bone regions, underneath tibial tray and around the stem, the geometry of stem had a more pronounced bone effect comparatively to the stem material. The results of this study support that short stems produce a minor effect in bone relatively to long stem in terms of stress shielding and stress concentration at tip region. No significant stress shielding differences was observed between Co-Cr and titanium stems. Overall, all stems provoked high stress concentrations in bone at the tip of the stem. Scintigraphy of a painful implanted knee showed local osteoblastic activity and radiographs evidence bone ossification at the distal tip of the stem due the stress concentration. The results show that long stems induce very high distal stresses and are more prone to induce pain. A new concept of long stem with a distal polymeric (flexible material) tip reduces the magnitude of stresses at the end of the stem and therefore can theoretically contribute to reduce pain.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Machines and control systems for friction stir welding: A review (2016)
Outra Publicação em Revista Científica Internacional
Mendes, N; Neto, P; Loureiro, A; António Paulo Moreira
Stress intensity factor and load transfer analysis of a cracked riveted lap joint (2007)
Artigo em Revista Científica Internacional
Moreira, PMGP; de Matos, PFP; Camanho, PP; Stefan D Pastrama; de Castro, PMST
Spinodal decomposition mechanism study on the duplex stainless steel UNS S31803 using ultrasonic speed measurements (2010)
Artigo em Revista Científica Internacional
Victor Hugo C. de Albuquerque; Edgard de Macedo Silva; Josinaldo Pereira Leite; Elineudo Pinho de Moura; Vera Lúcia de Araújo Freitas; João Manuel R.S. Tavares
Methodologies for failure analysis: a critical survey (2004)
Artigo em Revista Científica Internacional
Paulo M. S. T. de Castro; António Fernandes
Mechanical Characterization of Bone Cement using fiber Bragg grating sensors (2009)
Artigo em Revista Científica Internacional
C. Frias; O. Frazão; S. Tavares; A. Vieira ; A.T. Marques; J. Simões

Ver todas (13)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Economia da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Página gerada em: 2024-10-28 às 12:06:30 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias