Development of micro-flow devices by direct-milling on poly(methyl methacrylate) substrates with integrated optical detection

Título
Development of micro-flow devices by direct-milling on poly(methyl methacrylate) substrates with integrated optical detection
Tipo
Artigo em Revista Científica Internacional
Ano
2009
Autores
Eunice Rodrigues
(Autor)
FFUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Sem AUTHENTICUS Sem ORCID
Revista
Título: Mikrochimica ActaImportada do Authenticus Pesquisar Publicações da Revista
Vol. 166 3
Páginas: 189-195
ISSN: 0026-3672
Editora: Springer Nature
Indexação
Publicação em ISI Web of Science ISI Web of Science
Pubmed / Medline
Classificação Científica
FOS: Ciências médicas e da saúde > Outras ciências médicas
CORDIS: Ciências da Saúde
Outras Informações
ID Authenticus: P-003-GBM
Resumo (PT): The development of micro-flow devices by direct-milling on poly(methyl methacrylate) (PMMA) substrates and incorporating the optic detector into the same structure is presented, evaluated and applied to the determination of chlorhexidine. Hydrodynamic characteristics of the developed devices were compared against those obtained from flow systems based on classic Teflon reactors. The optical detector integrated in the PMMA substrate is composed of a light emitting diode (λ = 627 nm) and light dependence resistance as light source and light detector, respectively. The performance of the optical detector was evaluated and optimized. The applicability of the fluidic device was assessed in the determination of chlorhexidine through its colorimetric reaction with bromocresol green. Micro-pumps were used as propulsion units. Results obtained in real sample analysis were in good agreement with those obtained by the reference procedure. >br> <br> Keywords Microfluidic device - PMMA - Direct-milling - Optic detector integration - Multi-pumping - Chlorhexidine <br> <a target="_blank" href="http://www.springerlink.com/content/lt08g29374631271/?p=74bd3aeed6ba4beab2896ea6b875fe6e&pi=0"> Texto integral </a> <br> <br>
Abstract (EN): The development of micro-flow devices by direct-milling on poly(methyl methacrylate) (PMMA) substrates and incorporating the optic detector into the same structure is presented, evaluated and applied to the determination of chlorhexidine. Hydrodynamic characteristics of the developed devices were compared against those obtained from flow systems based on classic Teflon reactors. The optical detector integrated in the PMMA substrate is composed of a light emitting diode (λ = 627 nm) and light dependence resistance as light source and light detector, respectively. The performance of the optical detector was evaluated and optimized. The applicability of the fluidic device was assessed in the determination of chlorhexidine through its colorimetric reaction with bromocresol green. Micro-pumps were used as propulsion units. Results obtained in real sample analysis were in good agreement with those obtained by the reference procedure. <br> <br> Keywords Microfluidic device - PMMA - Direct-milling - Optic detector integration - Multi-pumping - Chlorhexidine <br> <a target="_blank" href="http://www.springerlink.com/content/lt08g29374631271/?p=74bd3aeed6ba4beab2896ea6b875fe6e&pi=0"> Full text </a> <br> <br>
Idioma: Português
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Dos mesmos autores

CMOS arrays as chemiluminescence detectors on microfluidic devices (2010)
Artigo em Revista Científica Internacional
Eunice R. G. O. Rodrigues; Rui A. S. Lapa
A Multicommutated Flow System Based on an Opened-Loop with Micropump Propulsion (2007)
Artigo em Revista Científica Internacional
Eunice R. G. O. Rodrigues ; Rui A. S. Lapa ; Jos L. F. C. Lima

Da mesma revista

The development and optimization of a modified single-drop microextraction method for organochlorine pesticides determination by gas chromatography-tandem mass spectrometry (2012)
Artigo em Revista Científica Internacional
Virginia C Fernandes; Viswanathan Subramanian; Nuno Mateus; Valentina F Domingues; Cristina Delerue Matos
Multi-syringe flow injection system with in-line pre-concentration for the determination of total phenolic compounds (2005)
Artigo em Revista Científica Internacional
Oliveira, HM; Segundo, MA; Reis, S; Lima, JLFC
Multi-syringe flow injection system for the determination of the scavenging capacity of the diphenylpicrylhydrazyl radical in methanol and ethanolic media (2007)
Artigo em Revista Científica Internacional
Luis M Magalhaes; Marcela A Segundo; Christophe Siquet; Salette Reis; Jose L F C Lima
Multi-pumping flow system for the determination of nitrite and nitrate in water samples (2008)
Artigo em Revista Científica Internacional
Carmen Pons; Joao L M Santos; Jose L F C Lima; Rafael Forteza; Victor Cerda

Ver todas (17)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Última actualização: 2016-03-23 I  Página gerada em: 2024-07-21 às 23:18:30 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias