Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Red blood cells tracking and cell-free layer formation in a microchannel with hyperbolic contraction: A CFD model validation

Red blood cells tracking and cell-free layer formation in a microchannel with hyperbolic contraction: A CFD model validation

Título
Red blood cells tracking and cell-free layer formation in a microchannel with hyperbolic contraction: A CFD model validation
Tipo
Artigo em Revista Científica Internacional
Ano
2022
Autores
Gracka, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Lima, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Miranda, JM
(Autor)
FEUP
Student, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Melka, B
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ostrowski, Z
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 226
ISSN: 0169-2607
Editora: Elsevier
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citações
Publicação em Scopus Scopus - 0 Citações
Outras Informações
ID Authenticus: P-00X-7AK
Abstract (EN): Background and Objective: In recent years, progress in microfabrication technologies has attracted the attention of researchers across disciplines. Microfluidic devices have the potential to be developed into powerful tools that can elucidate the biophysical behavior of blood flow in microvessels. Such devices can also be used to separate the suspended physiological fluid from whole in vitro blood, which includes cells. Therefore, it is essential to acquire a detailed description of the complex interaction between erythrocytes (red blood cells; RBCs) and plasma. RBCs tend to undergo axial migration caused by occurrence of the Fahraeus-Lindqvist effect. These dynamics result in a cell-free layer (CFL), or a low volume fraction of cells, near the vessel wall. The aim of the paper is to develop a numerical model capable of reproducing the behavior of multiphase flow in a microchannel obtained under laboratory conditions and to compare two multiphase modelling techniques Euler-Euler and Euler-Lagrange. Methods: In this work, we employed a numerical Computational Fluid Dynamics (CFD) model of the blood flow within microchannels with two hyperbolic contraction shapes. The simulation was used to reproduce the blood flow behavior in a microchannel under laboratory conditions, where the CFL formation is visible downstream of the hyperbolic contraction. The multiphase numerical model was developed using Euler-Euler and hybrid Euler-Lagrange approaches. The hybrid CFD simulation of the RBC transport model was performed using a Discrete Phase Model. Blood was assumed to be a nonhomogeneous mixture of two components: dextran, whose properties are consistent with plasma, and RBCs, at a hematocrit of 5% (percent by volume of RBCs). Results: The results show a 5 mu m thick CFL in a microchannel with a broader contraction and a 35 mu m thick CFL in a microchannel with a narrower contraction. The RBC volume fraction in the CFL is less than 2%, compared to 7-8% in the core flow. The results are consistent for both multiphase simulation techniques used. The simulation results were then validated against the experimentally-measured CFL in each of the studied microchannel geometries. Conclusions: Reasonable agreement between experiments and simulations was achieved. A validated model such as the one tested in this study can expedite the microchannel design process by minimizing the need to prefabricate prototypes and test them under laboratory conditions. (C) 2022 The Author(s). Published by Elsevier B.V.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 12
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Skin Lesion Computational Diagnosis of Dermoscopic Images: Ensemble Models based on Input Feature Manipulation (2017)
Artigo em Revista Científica Internacional
Roberta B. Oliveira; Aledir S. Pereira; João Manuel R. S. Tavares
Segmentation of ultrasound images of the carotid using RANSAC and cubic splines (2011)
Artigo em Revista Científica Internacional
Rui Rocha; Aurélio Campilho; Jorge A. Silva; Elsa Azevedo; Rosa Santos
Positive state observer for the automatic control of the depth of anesthesia-Clinical results (2019)
Artigo em Revista Científica Internacional
Filipa N. Nogueira; T. Mendonça; Maria Paula Rocha
PocketOnco®: Prototyping a mobile app for health literacy and self-management of oncological diseases (2025)
Artigo em Revista Científica Internacional
Cerqueira, F; Marta Campos Ferreira; Campos, MJ; Fernandes, CS

Ver todas (34)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Página gerada em: 2025-06-30 às 17:01:16 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias