Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Construction and evaluation of PVC and sol–gel sensor membranes based on Mn(III)TPP-Cl. Application to valproate determination in pharmaceutical preparations

Construction and evaluation of PVC and sol–gel sensor membranes based on Mn(III)TPP-Cl. Application to valproate determination in pharmaceutical preparations

Título
Construction and evaluation of PVC and sol–gel sensor membranes based on Mn(III)TPP-Cl. Application to valproate determination in pharmaceutical preparations
Tipo
Artigo em Revista Científica Internacional
Ano
2006
Autores
Emília M. G. Santos
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Alberto N. Araújo
(Autor)
FFUP
Cristina M. C. M. Couto
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
M. Conceição B. S. M. Montenegro
(Autor)
FFUP
Revista
Vol. 384 4
Páginas: 867-875
ISSN: 1618-2642
Editora: Springer Nature
Indexação
Pubmed / Medline
Classificação Científica
FOS: Ciências médicas e da saúde > Outras ciências médicas
CORDIS: Ciências da Saúde
Outras Informações
Resumo (PT): The construction and general performance of new valproate-selective electrodes based on manganese(III) tetraphenylporphyrin [Mn(III)TPP-Cl], as an ionophore, are presented. The ionophore was incorporated into PVC and ceramic membranes (sol–gel) based on methyltriethoxysilane. The influence of membrane composition and pH and the effect of lipophilic cationic and anionic additives in PVC membranes were investigated concerning their influence on the slope, response time, selectivity and lifetime of the electrodes. The PVC membrane without additive and the sol–gel membrane presented slopes and practical limits of detection of −60.8 mV dec−1 and 5x10−6 mol l−1 and −60.3 mV dec−1 and 1×10−4 mol l−1, respectively. The sol–gel membranes displayed higher selectivity for valproate when compared with PVC membranes. These two types of electrodes were coupled to a sequential-injection analysis (SIA) system for the direct determination of valproate in pharmaceutical formulations. The association of Mn(III)TPP-Cl with the sol–gel support inserted in a SIA system provided potentiometric sensors with an analytical range of 1x10−3–5x10−2 mol l−1, with a sample rate of 55 samples per hour and a sample and carrier consumption of 140 and 2,500 μl per determination, respectively. <br> <br> Keywords Valproate - Ion-selective electrodes - Potentiometry - Metalloporphyrins - Sol–gel - Sequential-injection analysis <br> <a target="_blank" href="http://www.springerlink.com/content/f6n1k516608m7377/ "> Texto integral </a> <br> <br>
Abstract (EN): The construction and general performance of new valproate-selective electrodes based on manganese(III) tetraphenylporphyrin [Mn(III)TPP-Cl], as an ionophore, are presented. The ionophore was incorporated into PVC and ceramic membranes (sol–gel) based on methyltriethoxysilane. The influence of membrane composition and pH and the effect of lipophilic cationic and anionic additives in PVC membranes were investigated concerning their influence on the slope, response time, selectivity and lifetime of the electrodes. The PVC membrane without additive and the sol–gel membrane presented slopes and practical limits of detection of −60.8 mV dec−1 and 5x10−6 mol l−1 and −60.3 mV dec−1 and 1×10−4 mol l−1, respectively. The sol–gel membranes displayed higher selectivity for valproate when compared with PVC membranes. These two types of electrodes were coupled to a sequential-injection analysis (SIA) system for the direct determination of valproate in pharmaceutical formulations. The association of Mn(III)TPP-Cl with the sol–gel support inserted in a SIA system provided potentiometric sensors with an analytical range of 1x10−3–5x10−2 mol l−1, with a sample rate of 55 samples per hour and a sample and carrier consumption of 140 and 2,500 μl per determination, respectively. <br> <br> Keywords Valproate - Ion-selective electrodes - Potentiometry - Metalloporphyrins - Sol–gel - Sequential-injection analysis <br> <a target="_blank" href="http://www.springerlink.com/content/f6n1k516608m7377/ "> Full text</a> <br> <br>
Idioma: Português
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Gold nanoparticles for the development of clinical diagnosis methods (2008)
Outra Publicação em Revista Científica Internacional
Pedro Baptista; Eulalia Pereira; Peter Eaton; Goncalo Doria; Adelaide Miranda; Ines Gomes; Pedro Quaresma; Ricardo Franco
Formation of pyranoanthocyanins in red wines: a new and diverse class of anthocyanin derivatives (2011)
Outra Publicação em Revista Científica Internacional
Victor de Freitas; Nuno Mateus
European analytical column number 47 (2019)
Outra Publicação em Revista Científica Internacional
Razic, S; Marcela A Segundo; Gauglitz, G
Celiac disease diagnosis and gluten-free food analytical control (2010)
Outra Publicação em Revista Científica Internacional
Marta Maria P D Pereira da Silva Neves; Maria B Begona Gonzalez Garcia; Hendrikus Petrus A Antonius Nouws; Cristina Delerue Matos; Alice Santos Silva; Agustin Costa Garcia

Ver todas (64)

Recomendar Página Voltar ao Topo