Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Electroanalytical Study of the Pesticide Asulam
Publication

Electroanalytical Study of the Pesticide Asulam

Title
Electroanalytical Study of the Pesticide Asulam
Type
Article in International Scientific Journal
Year
2002
Authors
Henri Nouws
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Cristina Delerue-Matos
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
E. Manuela Garrido
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pieter Vincke
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Noel Maes
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 82 No. 2
Pages: 69-76
ISSN: 0306-7319
Publisher: Taylor & Francis
Indexing
Scientific classification
FOS: Medical and Health sciences > Other medical sciences
CORDIS: Health sciences
Other information
Authenticus ID: P-000-QET
Resumo (PT): The electrochemical behaviour of the herbicide Asulam was studied by cyclic and square wave voltammetry. Asulam may be irreversibly oxidised at a glassy carbon electrode. Maximum currents were obtained at pH = 1.9 in aqueous electrolyte solution. Based on the electrochemical behaviour of Asulam, two analytical methodologies were developed for its determination in water samples, using square wave voltammetry (SWV) and flow injection analysis (FIA) coupled with an amperometric detector. Limits of detection of 7.1 10 -6 mol L -1 and 1.2 10 -8 mol L -1 for SWV and FIA respectively, were achieved. Repeatability was calculated by assessing the relative standard deviation (%) for 10 consecutive determinations of one sample. The found values were 2.1% for SWV and 5.0% for FIA. Validation of the results provided by SWV and FIA methodologies was performed by comparison with results from an HPLC-DAD technique. Good relative deviations were found (< 5%). Recovery trials were performed to assess the accuracy of the results and the obtained values were between 84% and 107% for both methods. <br> <br> Keywords: Asulam; Herbicides; Oxidation; Square Wave Voltammetry; Flow Injection Analysis; Amperometric Detection <br> <a target="_blank" href="http://www.informaworld.com/smpp/content~db=all~content=a713714602~frm=titlelink?waited=0"> Texto integral </a> <br> <br>
Abstract (EN): The electrochemical behaviour of the herbicide Asulam was studied by cyclic and square wave voltammetry. Asulam may be irreversibly oxidised at a glassy carbon electrode. Maximum currents were obtained at pH = 1.9 in aqueous electrolyte solution. Based on the electrochemical behaviour of Asulam, two analytical methodologies were developed for its determination in water samples, using square wave voltammetry (SWV) and flow injection analysis (FIA) coupled with an amperometric detector. Limits of detection of 7.1 10 -6 mol L -1 and 1.2 10 -8 mol L -1 for SWV and FIA respectively, were achieved. Repeatability was calculated by assessing the relative standard deviation (%) for 10 consecutive determinations of one sample. The found values were 2.1% for SWV and 5.0% for FIA. Validation of the results provided by SWV and FIA methodologies was performed by comparison with results from an HPLC-DAD technique. Good relative deviations were found (< 5%). Recovery trials were performed to assess the accuracy of the results and the obtained values were between 84% and 107% for both methods. <br> <br> Keywords: Asulam; Herbicides; Oxidation; Square Wave Voltammetry; Flow Injection Analysis; Amperometric Detection <br> <a target="_blank" href="http://www.informaworld.com/smpp/content~db=all~content=a713714602~frm=titlelink?waited=0"> Full text </a> <br> <br>
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Fluoroquinolones and sulfonamides: features of their determination in water. A review (2016)
Another Publication in an International Scientific Journal
Peixoto, PS; Toth, IV; Marcela A Segundo; Lima, JLFC
Tubular potentiometric detector used to determine As(V) in sediment extracts by flow injection (2006)
Article in International Scientific Journal
M. Beatriz Quinaz ; José L. F. C. Lima ; Enrique Barrado ; José A. Rodrguez
SPE sample pre-treatment using a mixed-mode sorbent of reverse-phase and ionic exchange for determination of ALMWOAs in waters (2014)
Article in International Scientific Journal
Rocha, ACS; Marisa M R Almeida; Clara C P Basto; M. Teresa S. D. Vasconcelos
Solid contact PVC membrane electrodes based on neutral or charged carriers for the selective reading of anionic sulfamethoxazole and their application to the analysis of aquaculture water (2012)
Article in International Scientific Journal
Almeida, SAA; Heitor, AM; Sa, LC; Barbosa, J; da Conceicao, M; Montenegro, MCBSM; Sales, MGF

See all (33)

Recommend this page Top