Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Simultaneous analysis of 23 priority volatile compounds in water by solid-phase microextraction-gas chromatography-mass spectrometry and estimation of the method's uncertainty
Publication

Simultaneous analysis of 23 priority volatile compounds in water by solid-phase microextraction-gas chromatography-mass spectrometry and estimation of the method's uncertainty

Title
Simultaneous analysis of 23 priority volatile compounds in water by solid-phase microextraction-gas chromatography-mass spectrometry and estimation of the method's uncertainty
Type
Article in International Scientific Journal
Year
2008
Authors
Ana Dias Guimarães
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
José João Carvalho
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Maria de Fátima Alpendurada
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications Without AUTHENTICUS Without ORCID
Carlos Gonçalves
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications Without AUTHENTICUS Without ORCID
Journal
Vol. 88 No. 3
Pages: 151-164
ISSN: 0306-7319
Publisher: Taylor & Francis
Scientific classification
FOS: Medical and Health sciences > Other medical sciences
CORDIS: Health sciences
Other information
Resumo (PT): Most water contaminations with volatile organic compounds (VOCs) are traceable to leaking underground fuel reservoirs, solvent storage vessels, agricultural practices, industrial residues, and deficient wastewater treatment and disposal. In order to perform effective monitoring of such organic micropollutants in a straightforward manner, a multiresidue method for the determination of 23 VOCs (trihalomethanes (THMs), BTEX and chlorinated solvents) in water has been developed using solid-phase microextraction (SPME) and capillary gas chromatography-mass spectrometry (GC-MS). This group includes also methyl-tert-butyl ether, epichlorhydrine, and vinyl chloride which present additional analytical difficulties. Three different fibres were assayed: 7-µm polydimethylsiloxane (PDMS), 100-µm PDMS, and 75-µm Carboxen-PDMS, and the extraction conditions were optimized. The best results for the majority of the analytes and mainly for those with the lowest signals were obtained using the Carboxen-PDMS fibre after 15 min of extraction in the headspace mode at a room temperature of 20 ± 2°C. The analytical sensitivity, linearity, precision, accuracy, and uncertainties have been studied for method validation in agreement with the international standard ISO/IEC 17025:2005. The limits of detection achieved with the proposed method (0.06-0.17 µg L-1) are adequate to determine the VOCs at the restrictive levels established by the European legislation. This was a decisive achievement to enable the analysis of all VOCs listed under the drinking-water directive in a single assay. The method exhibits performance capabilities suitable for routine analysis of VOCs in drinking-water by quality-control laboratories as enforced by EU Directives. The method is currently being used for this purpose, and participation in proficiency tests was assessed, with encouraging results. <br> <br> Keywords: SPME; Water; VOCs; Epichlorydrine; Vinyl chloride; MTBE; GC-MS; Uncertainty <br> <a target="_blank" href="http://www.informaworld.com/smpp/content~db=all~content=a790621571"> Texto integral</a> <br> <br>
Abstract (EN): Most water contaminations with volatile organic compounds (VOCs) are traceable to leaking underground fuel reservoirs, solvent storage vessels, agricultural practices, industrial residues, and deficient wastewater treatment and disposal. In order to perform effective monitoring of such organic micropollutants in a straightforward manner, a multiresidue method for the determination of 23 VOCs (trihalomethanes (THMs), BTEX and chlorinated solvents) in water has been developed using solid-phase microextraction (SPME) and capillary gas chromatography-mass spectrometry (GC-MS). This group includes also methyl-tert-butyl ether, epichlorhydrine, and vinyl chloride which present additional analytical difficulties. Three different fibres were assayed: 7-µm polydimethylsiloxane (PDMS), 100-µm PDMS, and 75-µm Carboxen-PDMS, and the extraction conditions were optimized. The best results for the majority of the analytes and mainly for those with the lowest signals were obtained using the Carboxen-PDMS fibre after 15 min of extraction in the headspace mode at a room temperature of 20 ± 2°C. The analytical sensitivity, linearity, precision, accuracy, and uncertainties have been studied for method validation in agreement with the international standard ISO/IEC 17025:2005. The limits of detection achieved with the proposed method (0.06-0.17 µg L-1) are adequate to determine the VOCs at the restrictive levels established by the European legislation. This was a decisive achievement to enable the analysis of all VOCs listed under the drinking-water directive in a single assay. The method exhibits performance capabilities suitable for routine analysis of VOCs in drinking-water by quality-control laboratories as enforced by EU Directives. The method is currently being used for this purpose, and participation in proficiency tests was assessed, with encouraging results. <br> <br> Keywords: SPME; Water; VOCs; Epichlorydrine; Vinyl chloride; MTBE; GC-MS; Uncertainty <br> <a target="_blank" href="http://www.informaworld.com/smpp/content~db=all~content=a790621571"> Full text </a> <br> <br>
Language: Portuguese
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Fluoroquinolones and sulfonamides: features of their determination in water. A review (2016)
Another Publication in an International Scientific Journal
Peixoto, PS; Toth, IV; Marcela A Segundo; Lima, JLFC
Tubular potentiometric detector used to determine As(V) in sediment extracts by flow injection (2006)
Article in International Scientific Journal
M. Beatriz Quinaz ; José L. F. C. Lima ; Enrique Barrado ; José A. Rodrguez
SPE sample pre-treatment using a mixed-mode sorbent of reverse-phase and ionic exchange for determination of ALMWOAs in waters (2014)
Article in International Scientific Journal
Rocha, ACS; Marisa M R Almeida; Clara C P Basto; M. Teresa S. D. Vasconcelos
Solid contact PVC membrane electrodes based on neutral or charged carriers for the selective reading of anionic sulfamethoxazole and their application to the analysis of aquaculture water (2012)
Article in International Scientific Journal
Almeida, SAA; Heitor, AM; Sa, LC; Barbosa, J; da Conceicao, M; Montenegro, MCBSM; Sales, MGF

See all (33)

Recommend this page Top