Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Spectrophotometric determination of iron and boron in soil extracts using a multi-syringe flow injection system

Spectrophotometric determination of iron and boron in soil extracts using a multi-syringe flow injection system

Título
Spectrophotometric determination of iron and boron in soil extracts using a multi-syringe flow injection system
Tipo
Artigo em Revista Científica Internacional
Ano
2005
Autores
Gomes, DMC
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Segundo, MA
(Autor)
REIT
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Rangel, AOSS
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Revista
Título: TalantaImportada do Authenticus Pesquisar Publicações da Revista
Vol. 66 3
Páginas: 703-711
ISSN: 0039-9140
Editora: Elsevier
Indexação
Classificação Científica
FOS: Ciências exactas e naturais > Química
CORDIS: Ciências da Saúde
Outras Informações
ID Authenticus: P-000-3S0
Resumo (PT): In the last decade, significant advances in flow analysis have been reported, namely the extensive use of computer-controlled devices to enhance the autonomy and performance of analysers. In the present work, computer-controlled multi-syringe flow injection systems are proposed to perform the spectrophotometric determination of available iron and boron in soil extracts. The methodologies were based on the formation of ferroin complex (determination of iron) and azomethine-H reaction (determination of boron). Both determinations were performed in manifolds with similar configurations by changing the reagents present in the different syringes. In the determination of iron, elimination of Schlieren effect in the detection system was achieved through the binary sampling approach, where a three-way valve was actuated to intercalate small slugs of sample and reagent, promoting better mixing conditions for solutions with different values of refractive index. In the determination of boron, in-line sample blank measurement was attained by omitting the introduction of reagent through software control, without manifold reconfiguration. Linear calibration curves were established between 0.50 and 10.0 mg Fe l−1 and between 0.20 and 4.0 mg B l−1. No systematic difference was found when soil extracts were analysed by the proposed methodologies and compared to the respective reference procedures. <br> <br> Keywords: Multi-syringe; Boron; Iron; Soil extracts; Spectrophotometry; Flow injection <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6THP-4F65KB1-5&_user=2460038&_coverDate=04%2F30%2F2005&_rdoc=27&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235288%232005%23999339996%23596297%23FLA%23display%23Volume)&_cdi=5288&_sort=d&_docanchor=&_ct=40&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=8531d37f5899c194e0d6904a517af652"> Texto integral</a> <br> <br>
Abstract (EN): In the last decade, significant advances in flow analysis have been reported, namely the extensive use of computer-controlled devices to enhance the autonomy and performance of analysers. In the present work, computer-controlled multi-syringe flow injection systems are proposed to perform the spectrophotometric determination of available iron and boron in soil extracts. The methodologies were based on the formation of ferroin complex (determination of iron) and azomethine-H reaction (determination of boron). Both determinations were performed in manifolds with similar configurations by changing the reagents present in the different syringes. In the determination of iron, elimination of Schlieren effect in the detection system was achieved through the binary sampling approach, where a three-way valve was actuated to intercalate small slugs of sample and reagent, promoting better mixing conditions for solutions with different values of refractive index. In the determination of boron, in-line sample blank measurement was attained by omitting the introduction of reagent through software control, without manifold reconfiguration. Linear calibration curves were established between 0.50 and 10.0 mg Fe l(-1) and between 0.20 and 4.0 mg Bl(-1). No systematic difference was found when soil extracts were analysed by the proposed methodologies and compared to the respective reference procedures.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 9
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Das mesmas áreas científicas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster em Conferência Nacional
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Outra Publicação em Revista Científica Internacional
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Outra Publicação em Revista Científica Internacional
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Outra Publicação em Revista Científica Internacional
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM
Volatile composition of Catharanthus roseus (L.) G. Don using solid-phase microextraction and gas chromatography/mass spectrometry (2009)
Artigo em Revista Científica Internacional
De Pinho, PG; Rui F Goncalves; Patricia Valentao; David M Pereira; Rosa M Seabra; Paula B Andrade; Mariana Sottomayor

Ver todas (159)

Da mesma revista

Recent developments, characteristics and potential applications of screen-printed electrodes in pharmaceutical and biological analysis (2016)
Outra Publicação em Revista Científica Internacional
Couto, RAS; Lima, JLFC; M. Beatriz Q. Garcia
Optical sensors and biosensors based on sol-gel films (2007)
Outra Publicação em Revista Científica Internacional
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Flow injection based methods for fast screening of antioxidant capacity (2009)
Outra Publicação em Revista Científica Internacional
Luis M Magalhaes; Miguel Santos; Marcela A Segundo; Salette Reis; Jose L F C Lima
Extraction and preconcentration techniques for chromatographic determination of chlorophenols in environmental and food samples (2012)
Outra Publicação em Revista Científica Internacional
Paulo de Morais; Teodor Stoichev; Clara C P Basto; Teresa T S D Vasconcelos

Ver todas (188)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Engenharia da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Página gerada em: 2024-07-21 às 23:19:50 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias