Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Ion selective electrodes for penicillin-G based on Mn(III)TPP-Cl and their application in pharmaceutical formulations control by sequential injection analysis

Ion selective electrodes for penicillin-G based on Mn(III)TPP-Cl and their application in pharmaceutical formulations control by sequential injection analysis

Título
Ion selective electrodes for penicillin-G based on Mn(III)TPP-Cl and their application in pharmaceutical formulations control by sequential injection analysis
Tipo
Artigo em Revista Científica Internacional
Ano
2004
Autores
Santos, EMG
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Araujo, AN
(Autor)
FFUP
Couto, CMCM
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Montenegro, MCBSM
(Autor)
FFUP
Kejzlarova, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Solich, P
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 36 4
Páginas: 701-709
ISSN: 0731-7085
Editora: Elsevier
Indexação
Classificação Científica
FOS: Ciências exactas e naturais > Química
CORDIS: Ciências da Saúde
Outras Informações
ID Authenticus: P-000-7PM
Resumo (PT): The work describes the construction, evaluation and analytical application of ion selective electrodes sensitive to penicillin-G antibiotics for pharmaceutical products analysis. Different types of polymeric membranes based on PVC (poly(vinyl chloride)) and EVA (ethyl-vinyl-acetate), without internal reference solution, were prepared using 5,10,15,20-tetraphenylporphyrinate (TPP) manganese(III) (Mn(III)TPP-Cl) as electroactive material. Different additives such as tetra-n-octylammoniumbromide (cationic additive) and sodium tetraphenylborate (anionic additive) were incorporated into the membranes to evaluate their influence on electrodes performance. The comparison of the developed detectors was based on general analytical characteristics, selectivity and lifetime. To accomplish the analysis of real samples, two selective membranes composed of 33.0% (w/w) of PVC, 66.0% (w/w) of o-NPOE and 1.0% (w/w) of Mn(III)TPP-Cl (type A) and 33.0% (w/w) of PVC, 66.0% (w/w) of o-NPOE, 1.0% (w/w) of Mn(III)TPP-Cl and 10% mol (relative to the molar concentration of Mn(III)TPP-Cl) of sodium tetraphenylborate (type B) were used. Type A electrode presented a linear response between 2 × 10−5 and 10−1 mol l−1 for penicillin-G, a slope of about −59 mV dec−1 and a reproducibility of about ±0.5 mV day−1, while type B exhibited a linear response between 5 × 10−5 and 10−1 mol l−1 for penicillin-G, a slope of about −61 mV dec−1 and a reproducibility of about ±0.3 mV day−1. The potentiometric analysis of penicillin-G in pharmaceutical products was carried out by direct potentiometry and the results obtained were compared with those provided by the HPLC reference method. These membranes (type A and type B) were used to prepare tubular electrodes that were coupled to a sequential injection system (SIA) and presented a linear range between 2 × 10−4 and 1 × 10−2 mol l−1 and slopes of −59.3 ± 0.8 and −57.3 ± 1.2 mV dec−1, respectively. The tubular electrode constructed using type B membrane (type TB) was used to carry out the potentiometric analysis of penicillin-G in pharmaceutical formulations. The proposed procedure enabled relative errors between 0.1% and 1.2% (n = 4) and a sampling-rate of about 25 samples per h. <br> <br> Keywords: Penicillin-G; Ion selective electrodes; SIA; Metalloporphyrins <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TGX-4DJ4VMX-1&_user=2460038&_coverDate=11%2F19%2F2004&_rdoc=4&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235266%232004%23999639995%23529441%23FLA%23display%23Volume)&_cdi=5266&_sort=d&_docanchor=&_ct=36&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=ddb84ebf160608a7719741c6e3bf4d0c"> Texto integral </a> <br> <br>
Abstract (EN): The work describes the construction, evaluation and analytical application of ion selective electrodes sensitive to penicillin-G antibiotics for pharmaceutical products analysis. Different types of polymeric membranes based on PVC (poly(vinyl chloride)) and EVA (ethyl-vinylacetate), without internal reference solution, were prepared using 5,10,15,20-tetraphenylporphyrinate (TPP) manganese(III) (Mn(III)TPP-Cl) as electroactive material. Different additives such as tetra-n-octylammoniumbromide (cationic additive) and sodium tetraphenylborate (anionic additive) were incorporated into the membranes to evaluate their influence on electrodes performance. The comparison of the developed detectors was based on general analytical characteristics, selectivity and lifetime. To accomplish the analysis of real samples, two selective membranes composed of 33.0% (w/w) of PVC, 66.0% (w/w) of o-NPOE and 1.0% (w/w) of Mn(III)TPP-Cl (type A) and 33.0% (w/w) of PVC, 66.0% (w/w) of o-NPOE, 1.0% (w/w) of Mn(III)TPP-Cl and 10% mol (relative to the molar concentration of Mn(III)TPP-Cl) of sodium tetraphenylborate (type B) were used. Type A electrode presented a linear response between 2 x 10(-5) and 10(-1) mol l(-1) for penicillin-G, a slope of about -59 mV dec(-1) and a reproducibility of about +/-0.5 mV day(-1), while type B exhibited a linear response between 5 x 10(-5) and 10(-1) mol l(-1) for penicillin-G, a slope of about -61 mV dec(-1) and a reproducibility of about +/-0.3 mV day(-1). The potentiometric analysis of penicillin-G in pharmaceutical products was carried out by direct potentiometry and the results obtained were compared with those provided by the HPLC reference method. These membranes (type A and type B) were used to prepare tubular electrodes that were coupled to a sequential injection system (SIA) and presented a linear range between 2 x 10(-4) and 1 x 10(-2) mol l(-1) and slopes of -59.3 +/- 10.8 and -57.3 +/- 1.2 mV dec(-1), respectively. The tubular electrode constructed using type B membrane (type TB) was used to carry out the potentiometric analysis of penicillin-G in pharmaceutical formulations. The proposed procedure enabled relative errors between 0.1% and 1.2% (n = 4) and a sampling-rate of about 25 samples per h.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 9
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Das mesmas áreas científicas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster em Conferência Nacional
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Outra Publicação em Revista Científica Internacional
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Outra Publicação em Revista Científica Internacional
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Outra Publicação em Revista Científica Internacional
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM
Volatile composition of Catharanthus roseus (L.) G. Don using solid-phase microextraction and gas chromatography/mass spectrometry (2009)
Artigo em Revista Científica Internacional
De Pinho, PG; Rui F Goncalves; Patricia Valentao; David M Pereira; Rosa M Seabra; Paula B Andrade; Mariana Sottomayor

Ver todas (159)

Da mesma revista

Modelling skin wound healing angiogenesis: A review (2019)
Outra Publicação em Revista Científica Internacional
Guerra, A; Belinha, J; Renato Natal Jorge
Hybrid MS/NMR methods on the prioritization of natural products: Applications in drug discovery (2018)
Outra Publicação em Revista Científica Internacional
Nelson G. M. Gomes; David M Pereira; Patricia Valentao; Paula B Andrade
Application of sequential injection analysis to pharmaceutical analysis (2006)
Outra Publicação em Revista Científica Internacional
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM
Volatile composition of Catharanthus roseus (L.) G. Don using solid-phase microextraction and gas chromatography/mass spectrometry (2009)
Artigo em Revista Científica Internacional
De Pinho, PG; Rui F Goncalves; Patricia Valentao; David M Pereira; Rosa M Seabra; Paula B Andrade; Mariana Sottomayor
VITAMIN-B1 AND VITAMIN-B6 TUBULAR ELECTRODES AS FIA DETECTORS - THEIR USE IN THE ANALYSIS OF PHARMACEUTICAL PRODUCTS (1991)
Artigo em Revista Científica Internacional
LIMA, JLFC; MONTENEGRO, MCBSM; SILVA, AMR

Ver todas (67)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Engenharia da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Página gerada em: 2024-11-03 às 04:49:14 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias