Você está em: Início > Publicações > Visualização > Quantification of 1-(propan-2-ylamino)-4-propoxy-9H-thioxanthen-9-one (TX5), a newly synthetized P-glycoprotein inducer/activator, in biological samples: method development and validation

Quantification of 1-(propan-2-ylamino)-4-propoxy-9H-thioxanthen-9-one (TX5), a newly synthetized P-glycoprotein inducer/activator, in biological samples: method development and validation

Título
Quantification of 1-(propan-2-ylamino)-4-propoxy-9H-thioxanthen-9-one (TX5), a newly synthetized P-glycoprotein inducer/activator, in biological samples: method development and validation
Tipo
Artigo em Revista Científica Internacional
Ano
2017
Autores
Ferreira, AF
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ponte, F
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Silva, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Rocha Pereira, C
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Emilia Sousa
(Autor)
FFUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Pinto, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Maria de Lourdes Bastos
(Autor)
FFUP
Fernando Remiao
(Autor)
FFUP
Revista
Vol. 31
Página Final: e3802
ISSN: 0269-3879
Editora: Wiley-Blackwell
Outras Informações
ID Authenticus: P-00M-K8X
Abstract (EN): A simple, rapid and economical method was developed and validated for the analysis and quantification of 1-(propan-2-ylamino)-4-propoxy-9H-thioxanthen-9-one (TX5), a P-glycoprotein inducer/activator, in biological samples, using reverse-phase high-performance liquid chromatography (HPLC). A C-18 column and a mobile phase composed of methanol-water (90/10, v/v) with 1% (v/v) triethylamine, at a flow rate of 1 mL/min, were used for chromatographic separation. TX5 standards (0.5-150 mu M) were prepared in human serum. Methanol was used for TX5 extraction and serum protein precipitation. After filtration, samples were injected into the HPLC apparatus and TX5 was quantified by a conventional UV detector at 255 nm. The TX5 retention time was 13 min in this isocratic system. The method was validated according to ICH guidelines for specificity/selectivity, linearity, accuracy, precision, limits of detection and quantification (LOD and LOQ) and recovery. The method was proved to be selective, as there were no interferences of endogenous compounds with the same retention time of TX5. Also, the developed method was linear (r(2) = 0.99) for TX5 concentrations between 0.5 and 150 mu M and the LOD and LOQ were 0.08 and 0.23 mu M, respectively. The results indicated that the reported method could meet the requirements for TX5 analysis in the trace amounts expected to be present in biological samples.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 7
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Quantification of paraquat in postmortem samples by gas chromatography-ion trap mass spectrometry and review of the literature (2012)
Outra Publicação em Revista Científica Internacional
Pedro Nuno Moreira; de Pinho, PG; Maria Teresa Baltazar; Maria Lourdes Bastos; Felix Carvalho; Ricardo Jorge Dinis Oliveira
Liquid chromatographic methods for the therapeutic drug monitoring of methotrexate as clinical decision support for personalized medicine: A brief review (2018)
Outra Publicação em Revista Científica Internacional
Silva, MF; Ribeiro, C; Goncalves, VMF; Tiritan M.E.; Lima, A
Vortex-assisted liquid-liquid micro-extraction and high-performance liquid chromatography for a higher sensitivity methyl methacrylate determination in biological matrices (2014)
Artigo em Revista Científica Internacional
Tiago F A Sousa; Marta C Aniceto; Amorim, CG; Mariana Souto Lopes; Daniel Perez Mongiovi; Maria C B S M Montenegro; Alberto N Araujo
Validation of a high-performance liquid chromatography method for the determination of (-)-alpha-bisabolol from particulate systems (2009)
Artigo em Revista Científica Internacional
Andre Sao Pedro; Cassia Detoni; Domingos Ferreira; Elaine Cabral Albuquerque; Bruno Sarmento
The role of salivary peptides in dental caries (2005)
Artigo em Revista Científica Internacional
vitorino, r; lobo, mjc; duarte, jr; ferrer-correia, aj; domingues, pm; amado, fml

Ver todas (21)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Engenharia da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Página gerada em: 2024-07-21 às 11:19:48 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias