Go to:
Logótipo
You are here: Start > Publications > View > Medical staff monitoring in interventional cardiology: over apron dosemeter placement based on measurements and simulations
Novo Podcast FEUP em Viagem
Publication

Medical staff monitoring in interventional cardiology: over apron dosemeter placement based on measurements and simulations

Title
Medical staff monitoring in interventional cardiology: over apron dosemeter placement based on measurements and simulations
Type
Article in International Scientific Journal
Year
2024
Authors
Ferrari, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Venturi, G
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Campani, L
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Mariotti, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Becker, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Jansen, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Jovanovic, Z
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Krstic, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Teles, P
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 200
Pages: 802-807
ISSN: 0144-8420
Other information
Authenticus ID: P-010-E6A
Abstract (EN): Interventional cardiology is characterized by high radiation exposure for both the patient and the operator. Adequate shielding and monitoring of the operator are fundamental to comply with radiation protection principles. In a previous work, the effect on the dose of the dosemeter position on the chest was studied. In this paper, the investigation has been completed, employing an anthropomorphic thorax phantom, equipped with arms. Although there are differences between the Monte Carlo simulations and the measurements, similar trends are observed, showing that the reduction in dose, due to the arms, is between 20 and 60%, compared with the situation without arms. For that reason, considering a dosemeter placed on the chest, the upper position, which is the least affected by the arms, should be preferred while the extreme lateral position, near the armpit, should be avoided.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 6
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

On the placement of apron dosemeters and dose assessment in interventional cardiology procedures: preliminary results (vol 198, pg 1495, 2022) (2023)
Other Publications
Ferrari, P; Becker, F; Campani, L; Jansen, J; Jovanovic, Z; Krstic, D; Mariotti, F; Teles, P; Venturi, G

Of the same journal

A REVIEW OF RADIATION PROTECTION REQUIREMENTS AND DOSE ESTIMATION FOR STAFF AND PATIENTS IN CT FLUOROSCOPY (2017)
Another Publication in an International Scientific Journal
Teles, P; Nikodemova, D; Bakhanova, E; Becker, F; Knezevic, Z; Pereira, MF; Sarmento, S
Study of nuclear medicine practices in Portugal from an internal dosimetry perspective (2012)
Article in International Scientific Journal
Bento, J; Teles, P; Neves, M; Santos, AI; Cardoso, G; Barreto, A; Alves, F; Guerreiro, C; Rodrigues, A; Santos, JAM; Capelo, C; Parafita, R; Martins, B
PERFORMANCE ASSESSMENT AND UNCERTAINTY EVALUATION OF A PORTABLE NAI-BASED DETECTION SYSTEM USED FOR THYROID MONITORING (2012)
Article in International Scientific Journal
Bento, J; Martins, B; Teles, P; Neves, M; Colarinha, P; Alves, F; Teixeira, N; Vaz, P; Zankl, M
On the Placement of Apron Dosemeters and Dose Assessment in Interventional Cardiology Procedures: Preliminary Results (2022)
Article in International Scientific Journal
Ferrari, P; Becker, F; Campani, L; Jansen, J; Jovanovie, Z; Krstie, D; Mariotti, F; Teles, P; Venturi, G
Monte Carlo simulation of the movement and detection efficiency of a whole-body counting system using a BOMAB phantom (2012)
Article in International Scientific Journal
Bento, J; Barros, S; Teles, P; Neves, M; Goncalves, I; Corisco, J; Vaz, P

See all (15)

Recommend this page Top
Copyright 1996-2026 © Faculdade de Engenharia da Universidade do Porto  I Terms and Conditions  I Accessibility  I Index A-Z  I Guest Book
Page generated on: 2026-02-28 at 13:04:07 | Acceptable Use Policy | Data Protection Policy | Complaint Portal