Go to:
Logótipo
You are here: Start > Publications > View > Automatic flow methodology for kinetic and inhibition studies of reactions with poorly water-soluble substrates in ionic liquid systems
Horário de verão da Biblioteca
Publication

Automatic flow methodology for kinetic and inhibition studies of reactions with poorly water-soluble substrates in ionic liquid systems

Title
Automatic flow methodology for kinetic and inhibition studies of reactions with poorly water-soluble substrates in ionic liquid systems
Type
Article in International Scientific Journal
Year
2011
Authors
Andre R T S Araujo
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lucia L M F S Saraiva
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 690 No. 1
Pages: 101-107
ISSN: 0003-2670
Publisher: Elsevier
Indexing
Publicação em ISI Web of Science ISI Web of Science
Pubmed / Medline
Scientific classification
CORDIS: Health sciences > Pharmacological sciences
FOS: Natural sciences > Chemical sciences
Other information
Authenticus ID: P-002-T63
Resumo (PT): In the present work an automatic generic tool, based on sequential injection analysis (SIA) for kinetic and inhibition studies of reactions with poorly water-soluble compounds in ionic liquid (IL)-containing systems, is described. The oxidation of the poorly water-soluble phenolic compound, caffeic acid, catalyzed by the mushroom tyrosinase, in different 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF4])/buffer mixtures as reaction media, was investigated. This determination was based on measuring depletion rate of the substrate caffeic acid at its maximum wavelength (λmax 311 nm). The influence of several parameters such as substrate and enzyme concentration, temperature, pH, delay times and measurement periods on the sensitivity and performance of the SIA system were studied and the optimum reaction conditions subsequently selected. The obtained results showed that tyrosinase was active in oxidising caffeic acid in this water-miscible IL and the presence of an impaired tyrosinase activity with increase in [bmim][BF4] concentration as an increase in the apparent Michaelis–Menten constant () was observed while the maximum reaction rate () remained fairly constant. The results were compared to those obtained when the assay was performed in water/methanol mixtures under the same conditions to substantiate [bmim][BF4] as an alternative to conventional organic solvents. Additionally, it was shown that tyrosinase is effectively inhibited by the substrate analogues tested (trans-cinnamic acid and 3,4-dihydroxybenzoic acid) in the IL-containing aqueous system used. <br> <br> Keywords: Ionic liquid; Sequential injection analysis; Kinetic; Inhibition; Tyrosinase <br> <a target="_blank" href="http://www.sciencedirect.com/science/article/pii/S0003267011001656 "> Texto integral </a> <br> <br>
Abstract (EN): In the present work an automatic generic tool, based on sequential injection analysis (SIA) for kinetic and inhibition studies of reactions with poorly water-soluble compounds in ionic liquid (IL)-containing systems, is described. The oxidation of the poorly water-soluble phenolic compound, caffeic acid, catalyzed by the mushroom tyrosinase, in different 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF(4)])/buffer mixtures as reaction media, was investigated. This determination was based on measuring depletion rate of the substrate caffeic acid at its maximum wavelength lambda(max) 311 nm). The influence of several parameters such as substrate and enzyme concentration, temperature, pH, delay times and measurement periods on the sensitivity and performance of the SIA system were studied and the optimum reaction conditions subsequently selected. The obtained results showed that tyrosinase was active in oxidising caffeic acid in this water-miscible IL and the presence of an impaired tyrosinase activity with increase in [bmim][BF(4)] concentration as an increase in the apparent Michaelis-Menten constant (K(M)(app)) was observed while the maximum reaction rate (V(max)(app)) remained fairly constant. The results were compared to those obtained when the assay was performed in water/methanol mixtures under the same conditions to substantiate [bmim][BF4] as an alternative to conventional organic solvents. Additionally, it was shown that tyrosinase is effectively inhibited by the substrate analogues tested (trans-cinnamic acid and 3,4-dihydroxybenzoic acid) in the IL-containing aqueous system used.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 7
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Sequential injection system for phospholipase A(2) activity evaluation: Studies on liposomes using an environment-sensitive fluorescent probe (2009)
Article in International Scientific Journal
Andre R T S Araujo; Diana Gaspar; Marlene Lucio; Salette Reis; Lucia L M F S Saraiva; Jose L F C Lima
Flow system for the automatic screening of the effect of phenolic compounds on the luminol-hydrogen peroxide-peroxidase chemiluminescence system (2011)
Article in International Scientific Journal
Andre R T S Araujo; Fernando Maya; Lucia L M F S Saraiva; Jose L F C Lima; Jose M Estela; Victor Cerda
Flow methodology for methanol determination in biodiesel exploiting membrane-based extraction (2008)
Article in International Scientific Journal
Andre R T S Araujo; Lucia L M F S Saraiva; Jose L F C Lima; Gracas G A Korn
Flow Injection Analysis with Immobilized Enzymes in Nonaqueous Media (2010)
Article in International Scientific Journal
Andre R T S Araujo; Lucia L M F S Saraiva; Jose L F C Lima
Determination of total and oxidized glutathione in human whole blood with a sequential injection analysis system (2008)
Article in International Scientific Journal
Andre R T S Araujo; Lucia L M F S Saraiva; Jose L F C Lima

See all (6)

Of the same scientific areas

Universal approach for mesofluidic handling of bead suspensions in lab-on-valve format (2011)
Article in International Scientific Journal
Hugo M Oliveira; Manuel Miro; Marcela A Segundo; Jose L F C Lima
Tetracycline Potentiometric Sensor Based on Cyclodextrin for Pharmaceuticals and Waste Water Analysis (2010)
Article in International Scientific Journal
Claudia O Cunha; Rita C R Silva; Celia G Amorim; Severino A Junior; Alberto N Araujo; Maria C B S M Montenegro; Valdinete L Silva
Spectrophotometric Determination of Bromate in Water Using Multisyringe Flow Injection Analysis (2011)
Article in International Scientific Journal
Sara M Oliveira; Marcela A Segundo; Antonio O S S Rangel; Jose L F C Lima; Victor Cerda
Sequential Injection Chemiluminescence Methodology for Ozone Evaluation (2011)
Article in International Scientific Journal
Daniele C M B dos Santos; Gracas G A Korn; Mauro Korn; Paula C A G Pinto; Lucia L M F S Saraiva; Jose L F C Lima
SEQUENTIAL INJECTION ANALYSIS SYSTEM WITH SPECTROPHOTOMETRIC DETECTION FOR DETERMINATION OF NORFLOXACIN AND CIPROFLOXACIN IN PHARMACEUTICAL FORMULATIONS (2011)
Article in International Scientific Journal
Jose Luiz Rufino; Helena Redigolo Pezza; Leonardo Pezza; Paula C A G Pinto; Lucia L M F S Saraiva; Jose L F C Lima

See all (9)

Of the same journal

Sequential injection analysis using electrochemical detection: A review (2005)
Another Publication in an International Scientific Journal
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
SEQUENTIAL FLOW-INJECTION DETERMINATIONS OF CALCIUM AND MAGNESIUM IN WATERS (1986)
Another Publication in an International Scientific Journal
ALONSO, J; BARTROLI, J; Lima, JLFC; MACHADO, AASC
Papers presented at the 10th International Conference on Flow Analysis Porto, Portugal, 3-8 September 2006 - Foreword (2007)
Another Publication in an International Scientific Journal
Purnendu Dasgupta; Jose L F C Lima; Lucia Saraiva; Marcela Segundo
Optical probes for detection and quantification of neutrophils' oxidative burst. A review (2009)
Another Publication in an International Scientific Journal
Marisa Freitas; Jose L F C Lima; Eduarda Fernandes
Nanoparticle-based assays in automated flow systems: A review (2015)
Another Publication in an International Scientific Journal
Marieta L C Passos; Paula C A G Pinto; Joao L M Santos; Lucia L M F S Saraiva; Andre R T S Araujo

See all (217)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Engenharia da Universidade do Porto  I Terms and Conditions  I Accessibility  I Index A-Z  I Guest Book
Page generated on: 2024-08-24 at 16:15:18 | Acceptable Use Policy | Data Protection Policy | Complaint Portal