Determination of total and oxidized glutathione in human whole blood with a sequential injection analysis system

Title
Determination of total and oxidized glutathione in human whole blood with a sequential injection analysis system
Type
Article in International Scientific Journal
Year
2008
Authors
Andre R T S Araujo
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lucia L M F S Saraiva
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Title: TalantaImported from Authenticus Search for Journal Publications
Vol. 74 No. 5
Pages: 1511-1519
ISSN: 0039-9140
Publisher: Elsevier
Indexing
Scientific classification
CORDIS: Health sciences
FOS: Natural sciences > Chemical sciences
Other information
Authenticus ID: P-004-1H1
Resumo (PT): This work reports the development of a simple, robust, automated sequential injection analysis (SIA) system for the enzymatic determination of total (tGSH) and oxidized (GSSG) glutathione in human whole blood. The reduced (GSH) glutathione concentration is then obtained as the difference between the tGSH and GSSG concentrations. The determination was based on the DTNB–GSSG reductase recycling assay, which couples the specificity of the GSSG reductase (GR) with an amplification of the response to glutathione, followed by spectrophotometric detection of the 2-nitro-5-thiobenzoic acid (TNB) formed (λ = 412 nm). The implementation of this reaction in a SIA flow system with an in-line dilution strategy permitted the necessary distinct application ranges for tGSH and for GSSG. It also guaranteed the exact timing of fluidic manipulations and precise control of the reaction conditions. The influence of parameters such as reagents concentration, temperature, pH, flow rate of the carrier buffer solution, as well as reaction coil length, etc., on the sensitivity and performance of the SIA system were studied and the optimum reaction conditions subsequently selected. Linear calibration plots were obtained for GSH and GSSG concentrations up to 3.00 and 1.50 μM, with detection limits of 0.031 and 0.014 μM, respectively. The developed methodology showed good precision, with a relative standard deviation (R.S.D.) < 5.0% (n = 10) for determination of both glutathione forms. Statistical evaluation showed good compliance, for a 95% confidence level, between the results obtained with the SIA system and those furnished by the comparison batch procedure. <br> <br> Keywords: Whole blood; Total and oxidized glutathione; Reduced glutathione; Glutathione reductase; SIA; In-line dilution <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6THP-4PTMXP0-1&_user=2460038&_coverDate=02%2F15%2F2008&_rdoc=58&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235288%232008%23999259994%23678809%23FLA%23display%23Volume)&_cdi=5288&_sort=d&_docanchor=&_ct=88&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=6e5c01fffbad40301eb9a0548d83c940"> Texto integral </a> <br> <br>
Abstract (EN): This work reports the development of a simple, robust, automated sequential injection analysis (SIA) system for the enzymatic determination of total (tGSH) and oxidized (GSSG) glutathione in human whole blood. The reduced (GSH) glutathione concentration is then obtained as the difference between. the tGSH and GSSG concentrations. The determination was based on the DTNB-GSSG reductase recycling assay, which couples the specificity of the GSSG reductase (GR) with an amplification of the response to glutathione, followed by spectrophotometric detection of the 2-nitro-5-thiobenzoic acid (TNB) formed (lambda = 412 nm). The implementation of this reaction in a SIA flow system with an in-line dilution strategy permitted the necessary distinct application ranges for tGSH and for GSSG. It also guaranteed the exact timing of fluidic manipulations and precise control of the reaction conditions. The influence of parameters such as reagents concentration, temperature, pH, flow rate of the carrier buffer solution, as well as reaction coil length, etc., on the sensitivity and performance of the SIA system were studied and the optimum reaction conditions subsequently selected. Linear calibration plots were obtained for GSH and GSSG concentrations up to 3.00 and 1.50 mu M, with detection limits of 0.031 and 0.014 mu M, respectively. The developed methodology showed good precision, with a relative standard deviation (R.S.D.) <5.0% (n = 10) for determination of both glutathione forms. Statistical evaluation showed good compliance, for a 95% confidence level, between the results obtained with the SIA system and those furnished by the comparison batch procedure. (C) 2007 Elsevier B.V. All rights reserved.
Language: English
Type (Professor's evaluation): Scientific
Notes: autor para correspondência
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Sequential injection system for phospholipase A(2) activity evaluation: Studies on liposomes using an environment-sensitive fluorescent probe (2009)
Article in International Scientific Journal
Andre R T S Araujo; Diana Gaspar; Marlene Lucio; Salette Reis; Lucia L M F S Saraiva; Jose L F C Lima
Flow system for the automatic screening of the effect of phenolic compounds on the luminol-hydrogen peroxide-peroxidase chemiluminescence system (2011)
Article in International Scientific Journal
Andre R T S Araujo; Fernando Maya; Lucia L M F S Saraiva; Jose L F C Lima; Jose M Estela; Victor Cerda
Flow methodology for methanol determination in biodiesel exploiting membrane-based extraction (2008)
Article in International Scientific Journal
Andre R T S Araujo; Lucia L M F S Saraiva; Jose L F C Lima; Gracas G A Korn
Flow Injection Analysis with Immobilized Enzymes in Nonaqueous Media (2010)
Article in International Scientific Journal
Andre R T S Araujo; Lucia L M F S Saraiva; Jose L F C Lima
Automatic miniaturized flow methodology with in-line solid-phase extraction for quinine determination in biological samples (2012)
Article in International Scientific Journal
Margarida Vaz, AM; Andre R T S Araujo; Joao L M Santos; Jose L F C Lima; Lucia L M F S Saraiva

See all (6)

Of the same scientific areas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster in a National Conference
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Another Publication in an International Scientific Journal
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Another Publication in an International Scientific Journal
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Another Publication in an International Scientific Journal
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM
Volatile composition of Catharanthus roseus (L.) G. Don using solid-phase microextraction and gas chromatography/mass spectrometry (2009)
Article in International Scientific Journal
De Pinho, PG; Rui F Goncalves; Patricia Valentao; David M Pereira; Rosa M Seabra; Paula B Andrade; Mariana Sottomayor

See all (159)

Of the same journal

Recent developments, characteristics and potential applications of screen-printed electrodes in pharmaceutical and biological analysis (2016)
Another Publication in an International Scientific Journal
Couto, RAS; Lima, JLFC; M. Beatriz Q. Garcia
Optical sensors and biosensors based on sol-gel films (2007)
Another Publication in an International Scientific Journal
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Flow injection based methods for fast screening of antioxidant capacity (2009)
Another Publication in an International Scientific Journal
Luis M Magalhaes; Miguel Santos; Marcela A Segundo; Salette Reis; Jose L F C Lima
Extraction and preconcentration techniques for chromatographic determination of chlorophenols in environmental and food samples (2012)
Another Publication in an International Scientific Journal
Paulo de Morais; Teodor Stoichev; Clara C P Basto; Teresa T S D Vasconcelos

See all (188)