Go to:
Logótipo
You are here: Start > Publications > View > Development of an inexpensive and rapidly preparable enzymatic pencil graphite biosensor for monitoring of glyphosate in waters
Clube de Leitura: Vamos a Livros || Verão com Histórias Dentro
Publication

Development of an inexpensive and rapidly preparable enzymatic pencil graphite biosensor for monitoring of glyphosate in waters

Title
Development of an inexpensive and rapidly preparable enzymatic pencil graphite biosensor for monitoring of glyphosate in waters
Type
Article in International Scientific Journal
Year
2023
Authors
Zambrano Intriago, LA
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Amorim, CG
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Araujo, AN
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Gritsok, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rodriguez Diaz, JM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Montenegro, MCBSM
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 855
ISSN: 0048-9697
Publisher: Elsevier
Other information
Authenticus ID: P-00X-78E
Abstract (EN): Glyphosate (GLY) is the most widely used non-selective broad-spectrum herbicide worldwide under well-reported side effects on the environment and human health. That's why it's necessary to control its presence in the environment. This work describes the development of an affordable, simple, and accurate electrochemical biosensor using a pencil graphite electrode as support, a horseradish peroxidase enzyme immobilized on a polysulfone membrane doped with multi -walled carbon nanotubes. The developed electrochemical sensor was used in the determination of GLY in river and drinking water samples. Cyclic voltammetry and amperometry were used as electrochemical detection techniques for the characterization and analytical application of the developed biosensor. The working mechanism of the biosensor is based on the inhibition of the peroxidase enzyme by GLY. Under optimal experimental conditions, the biosensor showed a linear response in the concentration range of 0.1 to 10 mg L-1. The limits of detection and quantification are 0.025 +/- 0.002 and 0.084 +/- 0.007 mg L-1, respectively, which covers the maximum residual limit established by the EPA for drinking water (0.7 mg L-1). The proposed biosensor demonstrated high reproducibility, excellent analytical performance, repeatability, and accuracy. The sensor proved to be selective against other pesticides, organic acids, and inorganic salts. Application on real samples showed recovery rates ranging between 98.18 +/- 0.11 % and 97.32 +/- 0.23 %. The analytical features of the proposed biosensor make it an effective and useful tool for the detection of GLY for environmental analysis.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 12
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

The prediction of PAHs bioavailability in soils using chemical methods: State of the art and future challenges (2014)
Another Publication in an International Scientific Journal
Cachada, A; Pereira, R; Ferreira da Silva, EF; Duarte, AC
The last frontier: Coupling technological developments with scientific challenges to improve hazard assessment of deep-sea mining (2018)
Another Publication in an International Scientific Journal
Santos, MM; Jorge, PAS; Coimbra, J; Vale, C; Caetano, M; Bastos, L; Iglesias, I; Guimarães, L; Reis Henriques, MA; Luis Oliva Teles; Vieira, MN; Raimundo, J; Pinheiro, M; Nogueira, V; Pereira, R; Neuparth, T; Ribeiro, MC; E. Pereira da Silva; Castro, LFC
Tannin-based coagulants: Current development and prospects on synthesis and uses (2022)
Another Publication in an International Scientific Journal
Tomasi, IT; Machado, CA; Boaventura, RAR; Cidália Botelho; Santos, SCR
Siderophores and metallophores: Metal complexation weapons to fight environmental pollution (2024)
Another Publication in an International Scientific Journal
Gomes, AFR; Almeida, MC; Emilia Sousa; Resende, DISP
Risk assessment of urban soils contamination: The particular case of polycyclic aromatic hydrocarbons (2016)
Another Publication in an International Scientific Journal
Cachada, A; Ferreira da Silva, EF; Duarte, AC; Ruth Pereira

See all (267)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Engenharia da Universidade do Porto  I Terms and Conditions  I Accessibility  I Index A-Z  I Guest Book
Page generated on: 2025-06-24 at 03:18:24 | Acceptable Use Policy | Data Protection Policy | Complaint Portal