Go to:
Logótipo
You are here: Start > Publications > View > A protocol proposal on calculation of the metabolic rate for surgeons in an operating room
Today is sunday
Perdidos e Achados - Destaque
Publication

A protocol proposal on calculation of the metabolic rate for surgeons in an operating room

Title
A protocol proposal on calculation of the metabolic rate for surgeons in an operating room
Type
Article in International Conference Proceedings Book
Year
2016
Authors
Nelson Rodrigues
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Alberto Miguel
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Senhorinha Teixeira
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
João Santos Baptista
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Conference proceedings International
Pages: 275-277
International Symposium on Occupational Safety and Hygiene
Guimarães, 23 a 24 de Março de 2016
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Other information
Authenticus ID: P-00M-5JJ
Abstract (EN): Thermal comfort is a subject of great importance for the well-being and productivity of people in general, thus, a good work environment is something that should be sought whenever possible. Within this subject, the determination of the metabolic rate has great importance, although its calculation can be a laborious task. In this work, a protocol is presented to calculate the metabolic rate of a surgeon when performing his work in an operating room. The clothing, environmental conditions as well as the different tasks of the surgeon were collected through observation of three surgeries in a Portuguese hospital. These conditions were then recreated on a controlled environment of a climatic chamber and a set of tasks to reproduce the physical workload performed by the surgeon. In this controlled environment, the metabolic rate was measured using oxygen measurement and the results were compared with ISO 8996: 2004 standard values. The obtained results showed a good approach to this standard.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 3
Related Publications

Of the same authors

One-way coupling between a CFD model and a transient thermal model of the human body (2014)
Chapter or Part of a Book
Senhorinha Teixeira; R. F. Oliveira; Nelson Rodrigues; Alberto Miguel; João Santos Baptista
Metabolic rate evaluation of an orthopaedic surgeon through oximetry (2017)
Article in International Conference Proceedings Book
Nelson Rodrigues; Alberto Miguel; Senhorinha Teixeira; João Santos Baptista
Evaluation of thermal comfort levels concerning the spatial arrangement in an operating room (2015)
Article in International Conference Proceedings Book
Nelson Rodrigues; Alberto Miguel; Senhorinha Teixeira; Celina Leão; João Santos Baptista
Recommend this page Top
Copyright 1996-2025 © Faculdade de Engenharia da Universidade do Porto  I Terms and Conditions  I Accessibility  I Index A-Z  I Guest Book
Page generated on: 2025-06-22 at 22:29:37 | Acceptable Use Policy | Data Protection Policy | Complaint Portal