Go to:
Logótipo
You are here: Start > Publications > View > Rational development of molecular imprinted carbon paste electrode for Furazolidone detection: theoretical and experimental approach
Horário de verão da Biblioteca
Publication

Rational development of molecular imprinted carbon paste electrode for Furazolidone detection: theoretical and experimental approach

Title
Rational development of molecular imprinted carbon paste electrode for Furazolidone detection: theoretical and experimental approach
Type
Article in International Scientific Journal
Year
2021
Authors
Rebelo, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pacheco, JG
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Andre Melo
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Natalia N D S Cordeiro
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Delerue Matos, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 329
ISSN: 0925-4005
Publisher: Elsevier
Other information
Authenticus ID: P-00T-1RY
Abstract (EN): Determination of antibiotics in environmental waters is an important global issue. Although furazolidone (FZD) was banned from use in food-producing animals, owing to its mutagenic and carcinogenic effects, this antibiotic has been illegally used across the world and its presence in environment have being noted. In this work, the first selective molecularly imprinted polymer (MIP) was developed for electrochemical detection of FZD. It was constructed based on the modification of the traditional carbon paste electrode (CPE) with MIP microparticles, followed by introduction of multi-walled carbon nanotubes (MWCNTs). Quantum mechanical (QM) calculations and molecular dynamics (MD) simulations were performed to allow rational selection of an appropriate functional monomer and to simulate the best pre-polymerisation conditions, respectively. The MIP were synthetized by polymerization using 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) as monomer and FZD as template molecule. The MIP microparticles were then incorporated on CPE-MWCNTs and the electrochemical analysis of FZD were evaluated by differential pulse voltammetry (DPV). After optimisation of experimental conditions, the MIP-CPE-MWCNTs sensor exhibited a good linear response over the concentration range of 0.01 mu M to 1 mu M with a correlation coefficient of 0.9995. The limit of detection (LOD) was found to be 0.03 mu M (S/N = 3). Due to high imprinting efficiency the sensor displayed selectivity to recognise FZD molecules and it was successfully applied in water samples where excellent recovery values (over 90 %) were obtained. The proposed sensor provides an efficient and promising sustainable strategy for monitorisation of FZD in environmental waters.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 11
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

p A simple electrochemical detection of atorvastatin based on disposable screen-printed carbon electrodes modified by molecularly imprinted polymer: Experiment and simulation (2022)
Article in International Scientific Journal
Rebelo, P; Pacheco, JG; Voroshylova, IV; Andre Melo; Natalia N D S Cordeiro; Delerue Matos, C

Of the same journal

Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies (2012)
Article in International Scientific Journal
Marta M P S Neves; Maria B Begona Gonzalez Garcia; Alice Santos Silva; Agustin Costa Garcia
Temperature compensation of a gas sensor for binary mixtures based on the permselectivity of polymeric membranes (2007)
Article in International Scientific Journal
Rosa Rego; Nídia Caetano; Adélio Mendes
Spectrophotometric sensor system based on a liquid waveguide capillary cell for the determination of titanium: Application to natural waters, sunscreens and a lake sediment (2011)
Article in International Scientific Journal
Ricardo N.M.J. Páscoa; Ildikó V. Tóth; Agostinho Almeida; António O.S.S. Rangel
Simultaneous measurement of refractive index and temperature using multimode interference inside a high birefringence fiber loop mirror (2013)
Article in International Scientific Journal
Gouveia, C; Chesini, G; Cordeiro, CMB; Baptista, JM; Jorge, PAS

See all (44)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Engenharia da Universidade do Porto  I Terms and Conditions  I Accessibility  I Index A-Z  I Guest Book
Page generated on: 2024-08-23 at 22:23:21 | Acceptable Use Policy | Data Protection Policy | Complaint Portal