Go to:
Logótipo
You are here: Start > Publications > View > Titanium dental implants coated with Bonelike((R)): Clinical case report
BIN@Porto 2024
Publication

Titanium dental implants coated with Bonelike((R)): Clinical case report

Title
Titanium dental implants coated with Bonelike((R)): Clinical case report
Type
Article in International Scientific Journal
Year
2006
Authors
Lobato, JV
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sooraj S Hussain
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Botelho, CM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Lobato, JM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lopes, MA
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Américo Afonso
(Author)
FMDUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Ali, N
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Santos, JD
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Title: Thin Solid FilmsImported from Authenticus Search for Journal Publications
Vol. 515
Pages: 279-284
ISSN: 0040-6090
Publisher: Elsevier
Indexing
Scientific classification
FOS: Engineering and technology > Materials engineering
CORDIS: Technological sciences > Engineering > Biomaterial engineering
Other information
Authenticus ID: P-004-H5E
Abstract (EN): The aim of the study was to evaluate the direct bone bonding and osteointegration of the commercial pure (cp Ti) implants coated with Bonelike (R) synthetic bone graft by plasma spraying. The Bonelike (R) coated implant was placed in the mandible of a 40-year-old patient and it was removed after a healing period of 3 months with a trephine of 6 mm diameter. The structure of the coating and new bone/implant interface of retrieved samples were evaluated using scanning electron microscopy (SEM) and histological analysis using light microscopy. In vivo microstructure observations of Bonelike (R) coated retrieved implants showed excellent bone remnants on its surface without any tissue and inflammatory signs observed. The reported Bonelike (R) coated (cp Ti) implants improved primary stability, which may increase the lifetime of the implant. Bonelike (R) coated dental implants proved to be highly bioactive with extensive new bone formation and strongly bonded to Bonelike (R) coating.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 6
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same scientific areas

Biomaterials and stem cell therapies for injuries associated to skeletal muscular tissues (2013)
Chapter or Part of a Book
Tiago Pereira; Andrea Gartner; Irina Amorim; Paulo Armada-da-Silva; Raquel Gomes; Cátia Pereira; Miguel L. França; Diana M. Morais; Miguel A. Rodrigues; Maria A. Lopes; José D. Santos; Ana Lúcia Luís; Ana Colette Maurício
3-D biomodelling technology for maxillofacial reconstruction (2008)
Article in International Scientific Journal
Manuel Oliveira; Sooraj S Hussain; Dias, AG; Lopes, MA; Luis Azevedo; Horacio Zenha; Horacio Costa; Santos, JD
Wear behaviour of stainless steel after Al2O3 plasma spraying for biomedical applications (1990)
Article in International Scientific Journal
José Domingos da Silva Santos; Fernando Jorge Mendes Monteiro
The effect of hydroxyapatite thickness on metal ion release from stainless steel substrates (1995)
Article in International Scientific Journal
S. Sousa; Mário Adolfo Monteiro da Rocha Barbosa
Synthesis and Characterization of Chitosan-Silicate Hydrogel as Resorbable Vehicle for Bonelike (R) Bone Graft (2009)
Article in International Scientific Journal
Yuki Shirosaki; Claudia M Botelho; Maria A Lopes; Jose D Santos

See all (33)

Of the same journal

The performance of Zr as barrier layer for Pt bottom electrodes in Pb(Zr,Ti)O-3 thin film capacitors (2005)
Article in International Scientific Journal
Mardare, CC; Joanni, E; Mardare, AI; Carlos Sá; Tavares, PB
The influence of silver on the structure and mechanical properties of (TiAl)-based intermetallics (1999)
Article in International Scientific Journal
Vieira, MT; Trindade, B; Ramos, AS; Fernandes, JV; Vieira, MF
Suppression of magnetostructural transition on GdSiGe thin film after thermal cyclings (2017)
Article in International Scientific Journal
Pires, AL; Belo, JH; Gomes, IT; Hadimani, RL; Schlagel, DL; Lograsso, TA; Jiles, DC; Lopes, AML; araujo, j. p.; pereira, a. m.
Structural study of Si1-xGex nanocrystals embedded in SiO2 films (2010)
Article in International Scientific Journal
Pinto, SRC; Kashtiban, RJ; Rolo, AG; Buljan, M; Chahboun, A; Bangert, U; Barradas, NP; Alves, E; Gomes, MJM
Structural properties of Ge nano-crystals embedded in SiO2 films from X-ray diffraction and Raman spectroscopy (1998)
Article in International Scientific Journal
Rolo, AG; Vasilevskiy, MI; Conde, O; Gomes, MJM

See all (32)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Engenharia da Universidade do Porto  I Terms and Conditions  I Accessibility  I Index A-Z  I Guest Book
Page generated on: 2024-10-01 at 20:20:36 | Acceptable Use Policy | Data Protection Policy | Complaint Portal