Recycling old screen-printed electrodes with newly designed plastic antibodies on the wall of carbon nanotubes as sensory element for in situ detection of bacterial toxins in water

Título
Recycling old screen-printed electrodes with newly designed plastic antibodies on the wall of carbon nanotubes as sensory element for in situ detection of bacterial toxins in water
Tipo
Artigo em Revista Científica Internacional
Ano
2013
Autores
Raquel B Queiros
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Guedes, A
(Autor)
FCUP
Marques, PVS
(Autor)
FCUP
Noronha, JP
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Sales, MGF
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Revista
Vol. 189
Páginas: 21-29
ISSN: 0925-4005
Editora: Elsevier
Classificação Científica
FOS: Ciências da engenharia e tecnologias > Outras ciências da engenharia e tecnologias
Outras Informações
ID Authenticus: P-008-G7P
Abstract (EN): Using low cost portable devices that enable a single analytical step for screening environmental contaminants is today a demanding issue. This concept is here tried out by recycling screen-printed electrodes that were to be disposed of and by choosing as sensory element a low cost material offering specific response for an environmental contaminant. Microcystins (MCs) were used as target analyte, for being dangerous toxins produced by cyanobacteria released into water bodies. The sensory element was a plastic antibody designed by surface imprinting with carefully selected monomers to ensure a specific response. These were designed on the wall of carbon nanotubes, taking advantage of their exceptional electrical properties. The stereochemical ability of the sensory material to detect MCs was checked by preparing blank materials where the imprinting stage was made without the template molecule. The novel sensory material for MCs was introduced in a polymeric matrix and evaluated against potentiometric measurements. Nernstian response was observed from 7.24 x 10(-10) to 1.28 x 10(-9) M in buffer solution (10 mM HEPES, 150 mM NaCl, pH 6.6), with average slopes of -62 mV decade(-1) and detection capabilities below 1 nM. The blank materials were unable to provide a linear response against log(concentration), showing only a slight potential change towards more positive potentials with increasing concentrations (while that of the plastic antibodies moved to more negative values), with a maximum rate of +33 mV decade(-1). The sensors presented good selectivity towards sulphate, iron and ammonium ions, and also chloroform and tetrachloroethylene (TCE) and fast response (<20 s). This concept was successfully tested on the analysis of spiked environmental water samples. The sensors were further applied onto recycled chips, comprehending one site for the reference electrode and two sites for different selective membranes, in a biparametric approach for "in situ" analysis.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 9
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies (2012)
Artigo em Revista Científica Internacional
Marta M P S Neves; Maria B Begona Gonzalez Garcia; Alice Santos Silva; Agustin Costa Garcia
Temperature compensation of a gas sensor for binary mixtures based on the permselectivity of polymeric membranes (2007)
Artigo em Revista Científica Internacional
Rosa Rego; Nídia Caetano; Adélio Mendes
Spectrophotometric sensor system based on a liquid waveguide capillary cell for the determination of titanium: Application to natural waters, sunscreens and a lake sediment (2011)
Artigo em Revista Científica Internacional
Ricardo N.M.J. Páscoa; Ildikó V. Tóth; Agostinho Almeida; António O.S.S. Rangel
Simultaneous measurement of refractive index and temperature using multimode interference inside a high birefringence fiber loop mirror (2013)
Artigo em Revista Científica Internacional
Gouveia, C; Chesini, G; Cordeiro, CMB; Baptista, JM; Jorge, PAS

Ver todas (44)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Última actualização: 2016-03-23 I  Página gerada em: 2024-08-23 às 08:32:42 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias