Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Randomized clinical study of injectable dextrin-based hydrogel as a carrier of a synthetic bone substitute
Mapa das Instalações
FC6 - Departamento de Ciência de Computadores FC5 - Edifício Central FC4 - Departamento de Biologia FC3 - Departamento de Física e Astronomia e Departamento GAOT FC2 - Departamento de Química e Bioquímica FC1 - Departamento de Matemática

Randomized clinical study of injectable dextrin-based hydrogel as a carrier of a synthetic bone substitute

Título
Randomized clinical study of injectable dextrin-based hydrogel as a carrier of a synthetic bone substitute
Tipo
Artigo em Revista Científica Internacional
Ano
2023
Autores
Machado, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Pereira, I
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Costa, F
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Brandao, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Pereira, JE
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Mauricio, AC
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Santos, JD
(Autor)
FEUP
Amaro, I
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Falacho, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Coelho, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Cruz, N
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Gama, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 27
Páginas: 979-994
ISSN: 1432-6981
Editora: Springer Nature
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citações
Outras Informações
ID Authenticus: P-00X-V4P
Abstract (EN): Objectives This study aimed to improve the performance and mode of administration of a glass-reinforced hydroxyapatite synthetic bone substitute, Bonelike by Biosckin (R) (BL (R)), by association with a dextrin-based hydrogel, DEXGEL, to achieve an injectable and moldable device named DEXGEL Bone. Methods Twelve participants requiring pre-molar tooth extraction and implant placement were enrolled in this study. BL (R) granules (250-500 mu m) were administered to 6 randomized participants whereas the other 6 received DEXGEL Bone. After 6 months, a bone biopsy of the grafted area was collected for histological and histomorphometric evaluation, prior to implant placement. The performance of DEXGEL Bone and BL (R) treatments on alveolar preservation were further analyzed by computed tomography and Hounsfield density analysis. Primary implant stability was analyzed by implant stability coefficient technique. Results The healing of defects was free of any local or systemic complications. Both treatments showed good osseointegration with no signs of adverse reaction. DEXGEL Bone exhibited increased granule resorption (p = 0.029) accompanied by a tendency for more new bone ingrowth (although not statistically significant) compared to the BL (R) group. The addition of DEXGEL to BL (R) granules did not compromise bone volume or density, being even beneficial for implant primary stability (p = 0.017). Conclusions The hydrogel-reinforced biomaterial exhibited an easier handling, a better defect filling, and benefits in implant stability. Clinical relevance This study validates DEXGEL Bone safety and performance as an injectable carrier of granular bone substitutes for alveolar ridge preservation.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 16
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Orofacial manifestations in outpatients with anorexia nervosa and bulimia nervosa focusing on the vomiting behavior (2017)
Artigo em Revista Científica Internacional
Lourenço, M.; Azevedo, Álvaro; Brandão, I.; Gomes PS
IRAK4 gene polymorphism and odontogenic maxillary sinusitis (2015)
Artigo em Revista Científica Internacional
Inês Pereira; Ricardo Faria e Almeida; Paula Vaz; Braga AC; António Felino
Genotoxicity of Root Canal Sealers: A Literature Review (2020)
Artigo em Revista Científica Internacional
Costa F; Fernandes MH; Batistuzzo de Medeiros S.

Ver todas (7)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Última actualização: 2016-03-23 I  Página gerada em: 2024-08-22 às 02:28:59 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias