Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > MnFe2O4@CNT-N as novel electrochemical nanosensor for determination of caffeine, acetaminophen and ascorbic acid
Mapa das Instalações
FC6 - Departamento de Ciência de Computadores FC5 - Edifício Central FC4 - Departamento de Biologia FC3 - Departamento de Física e Astronomia e Departamento GAOT FC2 - Departamento de Química e Bioquímica FC1 - Departamento de Matemática

MnFe2O4@CNT-N as novel electrochemical nanosensor for determination of caffeine, acetaminophen and ascorbic acid

Título
MnFe2O4@CNT-N as novel electrochemical nanosensor for determination of caffeine, acetaminophen and ascorbic acid
Tipo
Artigo em Revista Científica Internacional
Ano
2015
Autores
Diana M Fernandes
(Autor)
FCUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Silva, N
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
C. Moura
(Autor)
FCUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Magalhaes, JMCS
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Bachiller Baeza, B
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Rodriguez Ramos, I
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Guerrero Ruiz, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Delerue Matos, C
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 218
Páginas: 128-136
ISSN: 0925-4005
Editora: Elsevier
Outras Informações
ID Authenticus: P-00G-596
Abstract (EN): For the first time, a glassy carbon electrode (GCE) modified with novel N-doped carbon nanotubes (CNTN) functionalized with MnFe2O4 nanoparticles (MnFe2O4@CNT-N) has been prepared and applied for the electrochemical determination of caffeine (CF), acetaminophen (AC) and ascorbic acid (AA). The electrochemical behaviour of CF, AC and AA on the bare GCE, CNT-N/GCE and MnFe2O4@CNT-N/GCE were carefully investigated using cyclic voltammetry (CV) and square-wave voltammetry (SWV). Compared to bare GCE and CNT-N modified electrode, the MnFe2O4@CNT-N modified electrode can remarkably improve the electrocatalytic activity towards the oxidation of CF, AC and AA with an increase in the anodic peak currents of 52%, 50% and 55%, respectively. Also, the SWV anodic peaks of these molecules could be distinguished from each other at the MnFe2O4@CNT-N modified electrode with enhanced oxidation currents. The linear response ranges for the square wave voltammetric determination of CF, AC and AA were 1.0 x 10(-6) to 1.1 x 10(-3) mol dm(-3), 1.0 x 10(-6) to 1.0 x 10(-3) mol dm(-3) and 2.0 x 10(-6) to 1.0 x 10(-4) mol dm(-3) with detection limit (S/N= 3) of 0.83 x 10(-6), 0.83 x 10(-6) and 1.8 x 10(-6) mol dm(-3), respectively. The sensitivity values at the MnFe2O4@CNT-N/GCE for the individual determination of AC, AA and CF and in the presence of the other molecules showed that the quantification of AA and CF show no interferences from the other molecules; however, AA and CF interfered in the determination of AC, with the latter molecule showing the strongest interference. Nevertheless, the obtained results show that MnFe2O4@CNT-N composite material acted as an efficient electrochemical sensor towards the selected biomolecules.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 9
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Voltammetric immunosensor for the diagnosis of celiac disease based on the quantification of anti-gliadin antibodies (2012)
Artigo em Revista Científica Internacional
Marta M P S Neves; Maria B Begona Gonzalez Garcia; Alice Santos Silva; Agustin Costa Garcia
Temperature compensation of a gas sensor for binary mixtures based on the permselectivity of polymeric membranes (2007)
Artigo em Revista Científica Internacional
Rosa Rego; Nídia Caetano; Adélio Mendes
Spectrophotometric sensor system based on a liquid waveguide capillary cell for the determination of titanium: Application to natural waters, sunscreens and a lake sediment (2011)
Artigo em Revista Científica Internacional
Ricardo N.M.J. Páscoa; Ildikó V. Tóth; Agostinho Almeida; António O.S.S. Rangel
Simultaneous measurement of refractive index and temperature using multimode interference inside a high birefringence fiber loop mirror (2013)
Artigo em Revista Científica Internacional
Gouveia, C; Chesini, G; Cordeiro, CMB; Baptista, JM; Jorge, PAS

Ver todas (44)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Última actualização: 2016-03-23 I  Página gerada em: 2024-07-21 às 11:26:24 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias