Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > A compartmentalized neuron-oligodendrocyte co-culture device for myelin research: design, fabrication and functionality testing
Mapa das Instalações
FC6 - Departamento de Ciência de Computadores FC5 - Edifício Central FC4 - Departamento de Biologia FC3 - Departamento de Física e Astronomia e Departamento GAOT FC2 - Departamento de Química e Bioquímica FC1 - Departamento de Matemática

A compartmentalized neuron-oligodendrocyte co-culture device for myelin research: design, fabrication and functionality testing

Título
A compartmentalized neuron-oligodendrocyte co-culture device for myelin research: design, fabrication and functionality testing
Tipo
Artigo em Revista Científica Internacional
Ano
2019
Autores
Ristola, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Sukki, L
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Azevedo, MM
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Seixas, AI
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Relvas, JB
(Autor)
FMUP
Narkilahti, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Kallio, P
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Outras Informações
ID Authenticus: P-00Q-KQM
Abstract (EN): Microfluidics devices for co-culturing neurons and oligodendrocytes represent an important in vitro research tool to decipher myelination mechanisms in health and disease and in the identification of novel treatments for myelin diseases. In reported devices using primary rodent cells, the spontaneous formation of myelin sheaths has been challenging and random orientation of neurites impede the analysis of myelination. Furthermore, fabrication methods for devices show limitations, highlighting the need for novel in vitro cell-based myelination models. In the present study, we describe a compartmentalized cell culture device targeted for neuron-oligodendrocyte co-culturing and myelination studies. In the device, neurites from primary rat dorsal root ganglion (DRG) neurons were capable of forming aligned dense networks in a specific compartment that was physically isolated from neuronal somas. Co-culture of rat DRG neurons and oligodendrocytes, a well-known model to study myelination in vitro, led to interactions between oligodendrocytes and neurites in the device, and the deposition of myelin segments in an aligned distribution was spontaneously formed. For the fabrication of the device, we present a new method that produces polydimethylsiloxane (PDMS)-based devices possessing an open compartment design. The proposed fabrication method takes advantage of an SU-8 photolithography process and 3D printing for mould fabrication. Both the microscale and macroscale features are replicated from the same mould, allowing devices to be produced with high precision and repeatability. The proposed device is applicable for long-term cell culturing, live-cell imaging, and by enhancing aligned myelin distribution, it is a promising tool for experimental setups that address diverse biological questions in the field of myelin research.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 13
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Pre-distorted sinewave driven parallel-plate electrostatic actuator for harmonic displacement (2005)
Artigo em Revista Científica Internacional
G.Graaf, L. Mol, L.A. Rocha, E. Cretu, R.F. Wolffenbuttel
PDMS droplet formation and characterization by hydrodynamic flow focusing technique in a PDMS square microchannel (2016)
Artigo em Revista Científica Internacional
J. Carneiro; E. Doutel; J. B. L. M. Campos; J. M. Miranda
Measuring and interpreting the mechanicalthermal noise spectrum in a MEMS (2005)
Artigo em Revista Científica Internacional
L.A. Rocha, E. Cretu and R.F. Wolffenbuttel
Behavioural analysis of the pull-in dynamic transition (2004)
Artigo em Revista Científica Internacional
L. A. Rocha; E. Cretu; R. F. Wolffenbuttel
Application of gel-casting to the fabrication of 1-3 piezoelectric ceramic-polymer composites for high-frequency ultrasound devices (2012)
Artigo em Revista Científica Internacional
L. Garcia-Gancedo; S.M. Olhero; Jorge Lino; J.M.F. Ferreira; C.E.M. Demore; S. Cochran ; T.W. Button

Ver todas (6)

Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Última actualização: 2016-03-23 I  Página gerada em: 2024-07-21 às 15:30:58 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias