Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Potentiometric behaviour of ion selective electrodes based on iron porphyrins: The influence of porphyrin substituents on the response properties and analytical determination of diclofenac in pharmaceutical formulations

Potentiometric behaviour of ion selective electrodes based on iron porphyrins: The influence of porphyrin substituents on the response properties and analytical determination of diclofenac in pharmaceutical formulations

Título
Potentiometric behaviour of ion selective electrodes based on iron porphyrins: The influence of porphyrin substituents on the response properties and analytical determination of diclofenac in pharmaceutical formulations
Tipo
Artigo em Revista Científica Internacional
Ano
2006
Autores
Emilia M G Santos
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Alberto N Araujo
(Autor)
FFUP
Cristina M C M Couto
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Conceicao C B S M Montenegro
(Autor)
FFUP
Revista
Vol. 42 5
Páginas: 535-542
ISSN: 0731-7085
Editora: Elsevier
Indexação
Classificação Científica
FOS: Ciências exactas e naturais > Química
CORDIS: Ciências da Saúde
Outras Informações
ID Authenticus: P-004-G2G
Resumo (PT): The potentiometric response characteristics of diclofenac selective electrodes based on Fe(III) tetraphenylporphyrin-chloride (Fe(III)TPP-Cl) and Fe(III) tetrakis(pentafluorophenyl)porphyrin-chloride (Fe(III)TPFPP-Cl) in different mediator solvents and ionic additives are compared. The sensitivity, working range, detection limit, response mechanism, and selectivity of the membrane sensor show a significant dependence on the type of carrier substituent and on the pH value of the sample solution. Studies performed with different amounts of cationic additive (tetra-n-octylammoniumbromide (TOABr)) and anionic additive (sodium tetraphenylborate (NaTPB)) in the membranes allowed the determination of the potentiometric mechanism of action of the used metalloporphyrins. For the analysis of real samples, Fe(III)TPFPP-Cl (type G), prepared in o-NPOE, incorporating 10 mol% of TOABr, was used. This potentiometric unit presented a linear response towards diclofenac concentrations between 10−5 and 10−2 mol l−1 ( I = 0.1 mol l−1) and slopes of about −59 mV dec−1, exhibiting a response time of 10 s in a buffered solution of ammonia–ammonium sulphate with pH 9.9. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was carried out by direct potentiometry and the obtained results were compared to those provided by HPLC, presenting relative errors inferior to 1.0%. <br> <br> Keywords: Diclofenac; Ion selective electrodes; Potentiometry; Iron porphyrins <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TGX-4KD5BTX-1&_user=2460038&_coverDate=11%2F16%2F2006&_rdoc=3&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235266%232006%23999579994%23636174%23FLA%23display%23Volume)&_cdi=5266&_sort=d&_docanchor=&_ct=18&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=49e00dc7844f6697d858c44e00d51535"> Texto integral</a> <br> <br>
Abstract (EN): The potentiometric response characteristics of diclofenac selective electrodes based on Fe(III) tetraphenylporphyrin-chloride (Fe(III)TPP-Cl) and Fe(III) tetrakis(pentafluorophenyl)porphyrin-chloride (Fe(III)TPFPP-Cl) in different mediator solvents and ionic additives are compared. The sensitivity, working range, detection limit, response mechanism, and selectivity of the membrane sensor show a significant dependence on the type of carrier substituent and on the pH value of the sample solution. Studies performed with different amounts of cationic additive (tetra-n-octylammoniumbromide (TOABr)) and anionic additive (sodium tetraphenylborate (NaTPB)) in the membranes allowed the determination of the potentiometric mechanism of action of the used metalloporphyrins. For the analysis of real samples, Fe(III)TPFPP-Cl (type G), prepared in o-NPOE, incorporating 10 mol% of TOABr, was used. This potentiometric unit presented a linear response towards diclofenac concentrations between 10(-5) and 10(-2) mol l(-1) (l = 0.1 mol l(-1)) and slopes of about -59 mV dec(-1), exhibiting a response time of 10 s in a buffered solution of ammonia-ammonium sulphate with pH 9.9. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was carried out by direct potentiometry and the obtained results were compared to those provided by HPLC, presenting relative errors inferior to 1.0%.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 8
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Das mesmas áreas científicas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster em Conferência Nacional
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Outra Publicação em Revista Científica Internacional
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Outra Publicação em Revista Científica Internacional
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Outra Publicação em Revista Científica Internacional
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM

Ver todas (159)

Da mesma revista

Modelling skin wound healing angiogenesis: A review (2019)
Outra Publicação em Revista Científica Internacional
Guerra, A; Belinha, J; Renato Natal Jorge
Hybrid MS/NMR methods on the prioritization of natural products: Applications in drug discovery (2018)
Outra Publicação em Revista Científica Internacional
Nelson G. M. Gomes; David M Pereira; Patricia Valentao; Paula B Andrade
Application of sequential injection analysis to pharmaceutical analysis (2006)
Outra Publicação em Revista Científica Internacional
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM
Volatile composition of Catharanthus roseus (L.) G. Don using solid-phase microextraction and gas chromatography/mass spectrometry (2009)
Artigo em Revista Científica Internacional
De Pinho, PG; Rui F Goncalves; Patricia Valentao; David M Pereira; Rosa M Seabra; Paula B Andrade; Mariana Sottomayor

Ver todas (68)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-28 às 09:22:38 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico