Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Simulation of a Total Knee Arthroplasty System Based on Extended Reality

Simulation of a Total Knee Arthroplasty System Based on Extended Reality

Título
Simulation of a Total Knee Arthroplasty System Based on Extended Reality
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
2024
Autores
Lopes, C
(Autor)
FEUP
Armando Jorge Sousa
(Autor)
FEUP
Vilaca, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Santos, CP
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ata de Conferência Internacional
Páginas: 1-8
IEEE 12th International Conference on Serious Games and Applications for Health (SeGAH)
Madeira, PORTUGAL, AUG 07-09, 2024
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citações
Publicação em Scopus Scopus - 0 Citações
Outras Informações
ID Authenticus: P-016-Z6B
Abstract (EN): Total arthroplasty is one of the most common knee surgeries and, due to the ageing of the population, the number of procedures performed each year is expected to increase. With almost a quarter of patients dissatisfied, systems for computer assistance in orthopaedic surgery have been on the rise, appearing to have better outcomes than conventional techniques by reproducing a planned alignment with a similar learning curve. The search for inexpensive solutions to improve these prototypes is extremely relevant since most systems in the market involve expensive robots. The development of a simulation for an extended reality system, specifically spatial augmented reality, with a projector and a depth camera to project the desired total knee arthroplasty bone cuts onto a simulated knee joint has been proposed. It was created with Gazebo and communicates with the Robotic Operating System (ROS) framework so that it can easily be transposed to the real world. An evaluation of the simulator was performed regarding the projection's accuracy. The performance of the simulator was fitting for surgery, with the highest mean position error between the desired bone cut and the simulated bone cut of 1.11 +/- 0.86 mm (minimum = 0.00 mm, maximum = 2.60 mm) for the tibia cut. These values could be further improved with the implementation of a feature-matching algorithm and a dynamic projection.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 8
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-07-30 às 08:10:13 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico