Optimization of IGBT Switching by Adaptive Gate Control

Título
Optimization of IGBT Switching by Adaptive Gate Control
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
1995
Autores
Armando Araújo
(Autor)
FEUP
António Pina Martins
(Autor)
FEUP
Adriano Carvalho
(Autor)
FEUP
Ata de Conferência Internacional
Páginas: 227-230
38th Midwest Symposium on Circuits and Systems
Rio de Janeiro, Brasil
Outras Informações
Resumo (PT): The short circuit clearance in switching of PWM 3 phase inverters in a few industrial applications must be done in such a way that the maximum current and voltage ratings are not exceeded. The probability of frequent load short circuit, due to the load conditions, justifies the use of a special gate turn off scheme. As conventional RCD topologies should be avoided, in power inverters, due to additional stresses in the IGBT, owing to the interaction between the complementary snubber capacitors of an arm, this justifies the choice for a commutation aid and protection circuit based on a voltage limiter. Conventional drives, which have current commutation time optimised for the normal conditions of the converter, react fastly to the fault. This fast commutation diverts almost all the short circuit current to the limiter capacitor causing its overdimensioning, for the short circuit condition. If the short circuit current could be shared between the limiter and the power semiconductor the overvoltage may be reduced enabling the use of a capacitor with almost the same rating necessary for normal operation. This benefits the duties and working frequency. This paper presents the design and operation characteristics of a drive protection circuit ruling these characteristics.
Abstract (EN): The short circuit clearance in switching of PWM 3 phase inverters in a few industrial applications must be done in such a way that the maximum current and voltage ratings are not exceeded. The probability of frequent load short circuit, due to the load conditions, justifies the use of a special gate turn off scheme. As conventional RCD topologies should be avoided, in power inverters, due to additional stresses in the IGBT, owing to the interaction between the complementary snubber capacitors of an arm, this justifies the choice for a commutation aid and protection circuit based on a voltage limiter. Conventional drives, which have current commutation time optimised for the normal conditions of the converter, react fastly to the fault. This fast commutation diverts almost all the short circuit current to the limiter capacitor causing its overdimensioning, for the short circuit condition. If the short circuit current could be shared between the limiter and the power semiconductor the overvoltage may be reduced enabling the use of a capacitor with almost the same rating necessary for normal operation. This benefits the duties and working frequency. This paper presents the design and operation characteristics of a drive protection circuit ruling these characteristics.
Idioma: Português
Tipo (Avaliação Docente): Científica
Contacto: If you want copies send a message to asa@fe.up.pt.
Nº de páginas: 4
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Dos mesmos autores

The IGBT Transistor switching. A case study (1994)
Artigo em Livro de Atas de Conferência Internacional
Armando Araújo; António Quintas; Adriano Carvalho; António Pina Martins
Parallel Operation of Standard UPSs by Reactive Power Control (1995)
Artigo em Livro de Atas de Conferência Internacional
Armando Araújo; António Pina Martins; Adriano Carvalho
OPTIMUM SWITCHING IN IGBT TRANSISTOR (1994)
Artigo em Livro de Atas de Conferência Internacional
QUINTAS, AR; CARVALHO, A; ARAUJO, A; MARTINS, A
Modelling and simulation of a voltage source three phase active power filter (1995)
Artigo em Livro de Atas de Conferência Internacional
Martins, AP; Carvalho, AS; Araujo, AS
Modelling and Simulation of a Three Phase Voltage Source Active Power Filter (1995)
Artigo em Livro de Atas de Conferência Internacional
Armando Araújo; António Pina Martins; Adriano Carvalho