Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > COPSE - A NEW HIGH PERFORMANCE CONTROLLER FOR DRYING AND OIL FILLING OF DISTRIBUTION POWER TRANSFORMERS

COPSE - A NEW HIGH PERFORMANCE CONTROLLER FOR DRYING AND OIL FILLING OF DISTRIBUTION POWER TRANSFORMERS

Título
COPSE - A NEW HIGH PERFORMANCE CONTROLLER FOR DRYING AND OIL FILLING OF DISTRIBUTION POWER TRANSFORMERS
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
1994
Autores
QUINTAS, AR
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
CARVALHO, AS
(Autor)
FEUP
ARAUJO, AS
(Autor)
FEUP
MARTINS, AP
(Autor)
FEUP
OLIVIERA, JC
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ata de Conferência Internacional
Páginas: 425-429
5th International Conference on Power Electronics and Variable-Speed Drives (PEVD94)
LONDON, ENGLAND, OCT 26-28, 1994
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citações
Publicação em Scopus Scopus - 0 Citações
Classificação Científica
FOS: Ciências da engenharia e tecnologias > Engenharia electrotécnica, electrónica e informática
Outras Informações
ID Authenticus: P-001-KQB
Resumo (PT): The drying process of distribution transformers in manufacturing process is traditionally made by indirect heating of the windings of the transformer within an oven. This drying method causes low efficiency, high drying time, and associated lower quality for voltage isolation than the new method implemented by the authors and presented in this paper. The heating process has become a direct heating process, supplying the transformer in manufacturing with a low frequency inverter and losses nominal power. The direct heating method requires a framework involving a control system for the heating current and winding temperature, handling highly nonlinear regimens in the output range of high temperature. Static operation points of temperature cause a drop down to 1% of the nominal power. The mean windings temperature is measured and controlled during all the process. This paper shows the design, implementation and results with a high performance controller for this process.
Abstract (EN): The drying process of distribution transformers in manufacturing process is traditionally made by indirect heating of the windings of the transformer within an oven. This drying method causes low efficiency, high drying time, and associated lower quality for voltage isolation than the new method implemented by the authors and presented in this paper. The heating process has become a direct heating process, supplying the transformer in manufacturing with a low frequency inverter and losses nominal power. The direct heating method requires a framework involving a control system for the heating current and winding temperature, handling highly non-linear regimens in the output range of high temperature. Static operation points of temperature cause a drop of transformer input power down to 1% of the nominal power. The mean windings temperature is measured and controlled during all the process. This paper shows the design, implementation and results with a high performance controller for this process.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 5
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-07-24 às 06:19:34 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico