Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > The prostate health index and the percentage of [-2]proPSA maintain their diagnostic performance when calculated with total and free PSA from different manufacturers

The prostate health index and the percentage of [-2]proPSA maintain their diagnostic performance when calculated with total and free PSA from different manufacturers

Título
The prostate health index and the percentage of [-2]proPSA maintain their diagnostic performance when calculated with total and free PSA from different manufacturers
Tipo
Artigo em Revista Científica Internacional
Ano
2021
Autores
Garrido, MM
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ribeiro, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Pinheiro, LC
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Holdenrieder, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
guimaraes, jt
(Autor)
FMUP
Revista
Vol. 59
Páginas: 1869-1877
ISSN: 1434-6621
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citações
Publicação em Scopus Scopus - 0 Citações
Outras Informações
ID Authenticus: P-00V-EHA
Resumo (PT):
Abstract (EN): Objectives: To evaluate the diagnostic performance of the prostate health index (PHI) and of the percentage of [-2] proPSA (%[-2]proPSA) calculated with total and free PSA from non-Beckman Coulter manufacturers (Roche and Abbott), and compare it with the fully Beckman Coulter [-2] proPSA derivatives. Methods: In this study, 237 men (PSA: 2-10 mu g/L) scheduled for prostate biopsy were enrolled. %[-2]proPSA and PHI were calculated with total and free PSA from three manufacturers. Beckman Coulter PSA and [-2]proPSA were performed on the Access 2 analyzer (Hybritech calibration). Roche PSA was performed on the cobas e411 and the Abbott PSA on the Architect i2000sr. Statistical analysis was performed, considering prostate cancer (PCa) as the outcome. Results: Univariate analysis showed that all indices were predictors of cancer, irrespective of the manufacturer (p<0.001). The AUC was similar for all manufacturers, both for %[-2]proPSA (Beckman Coulter: 0.756; Roche: 0.770; Abbott: 0.756) and PHI (Beckman Coulter: 0.776; Roche: 0.785; Abbott: 0.778). When considering the cutoffs that allowed 90% sensitivity, [-2]proPSA derivatives calculated with Roche and Abbott PSA had similar specificities and predictive values when compared to Beckman Coulter. The percentage of missed cancers (8-9%) was the same between manufacturers. The percentage of spared biopsies was significantly higher with Roche's PHI (21.0%) and Abbott's PHI (20.6%) than with Beckman Coulter's PHI (17.2%). Conclusions: In the PSA range between 2 and 10 mu g/L, [-2] proPSA derivatives maintain their diagnostic performance in PCa detection when calculated with PSA from Roche and Abbott. This can lead to a broader implementation of these indices in clinical laboratories worldwide.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 9
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Comparison of Bio-Plex measurements with standard techniques (2012)
Outra Publicação em Revista Científica Internacional
Sandra Ribeiro; Henrique Nascimento; Ana Borges; Maria do Sameiro Faria; Petronila Rocha Pereira; Elisio Costa; Luis Belo; Alice Santos Silva
Automated detection of unstable hemoglobin variants by Sysmex XE-Series analyzers (2017)
Outra Publicação em Revista Científica Internacional
Teixeira, C; Pina, D; Freitas, MI
HOW DIFFERENT CAN DIRECT AND CALCULATED LOW-DENSITY LIPOPROTEIN CHOLESTEROL BE? (2011)
Outras Publicações
farinha, r; ramos, e; Severo M; guimaraes, jt
Using a High Value of Amylase or Lipase to Track the Patient Destination (2003)
Artigo em Revista Científica Internacional
Lopes F
The quality of the extra-analytical phase of laboratory practice in some developing European countries and Mexico - a multicentric study (2011)
Artigo em Revista Científica Internacional
simundic, am; bilic-zulle, l; nikolac, n; supak-smolcic, v; honovic, l; avram, s; beregovaja, e; dobreanu, m; guimaraes, jt; kovacs, gl; singh, nm; sierra-amor, ri; sypniewska, g; zima, t

Ver todas (9)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-26 às 08:49:06 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico