Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Analysis of the Traffic Induced Vibrations on a 19th Century Heritage Chapel using FEM Modelling

Analysis of the Traffic Induced Vibrations on a 19th Century Heritage Chapel using FEM Modelling

Título
Analysis of the Traffic Induced Vibrations on a 19th Century Heritage Chapel using FEM Modelling
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
2010
Autores
P. Tamvakou
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
M.M. Paredes
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ata de Conferência Internacional
Páginas: 1-16
The Tenth International Conference on Computational Structures Technology
Valencia-Spain, 14 a 17 de Setembro de 2010
Indexação
Publicação em ISI Proceedings ISI Proceedings
Publicação em ISI Web of Science ISI Web of Science
Publicação em Scopus Scopus
COMPENDEX
Classificação Científica
FOS: Ciências da engenharia e tecnologias > Engenharia civil
Outras Informações
Resumo (PT): To study the consequences of traffic vibrations on a patrimony chapel, a finite element method (FEM) modelling of the chapel and adjoining soil and road was developed using commercial software ANSYS [1]. The dynamic loads corresponding to vehicles moving along the road were simulated and the corresponding maximum displacements accelerations and stresses of some chapel key points were obtained. The dimensions of the heritage chapel are 4.91 m wide, 9.2 m long, 7.15 m high. To include the effect of the adjacent Manor-House, a small wall attached to the eastern side of the chapel in continuity of façade with the chapel southern front wall (9,82 m long), and a big wall attached to the eastern side of the chapel alongside its length (20 m long) were considered. The complex FEM model of the chapel-house-soil-road was meshed with 20-node brick elements. The first 3 modes of vibration had the natural frequencies: f1=16.23 Hz, f2=22.19 Hz and f3=24.85 Hz; they matched (with some accuracy) values obtained by system identification using 4 seismographs at 4 implantation points of the chapel and detecting the motion characteristics induced by ambient vibrations (Miguel [2]). As the hypothetical vehicle moves along the road, its weight is always between 2 road nodes. Some nodes were selected on the walls of the chapel, for which were explicitly calculated the displacements and the accelerations. When the vehicle is near the chapel wall, the displacements begin to increase up to the point that the wall reaches its maximum displacement. Some nonlinear graphs of normal and shear stresses variations were determined for the operating weight of a large hydraulic excavator on tracks as heavy circulating vehicle. Although the chapel structure might look safe for ultimate limit conditions that apparently do not reach critical stress values, the chapel behaviour indicates indexes and conditions which imply reduction or loss of serviceability. The peak sway ratios for this chapel under heavy traffic reached values only characteristic of much slender structures like masonry bell towers (Selby and Wilson [3]). Also, the calculated peak transient horizontal accelerations for several nodes on the west wall, far exceeded the peak recommended value of 42 mm/s2 defined in BS 6472 [4] for adverse human exposure to vibration in buildings. (Paper 140)
Abstract (EN): To study the consequences of traffic vibrations on a patrimony chapel, a finite element method (FEM) modelling of the chapel and adjoining soil and road was developed using commercial software ANSYS [1]. The dynamic loads corresponding to vehicles moving along the road were simulated and the corresponding maximum displacements accelerations and stresses of some chapel key points were obtained. The dimensions of the heritage chapel are 4.91 m wide, 9.2 m long, 7.15 m high. To include the effect of the adjacent Manor-House, a small wall attached to the eastern side of the chapel in continuity of façade with the chapel southern front wall (9,82 m long), and a big wall attached to the eastern side of the chapel alongside its length (20 m long) were considered. The complex FEM model of the chapel-house-soil-road was meshed with 20-node brick elements. The first 3 modes of vibration had the natural frequencies: f1=16.23 Hz, f2=22.19 Hz and f3=24.85 Hz; they matched (with some accuracy) values obtained by system identification using 4 seismographs at 4 implantation points of the chapel and detecting the motion characteristics induced by ambient vibrations (Miguel [2]). As the hypothetical vehicle moves along the road, its weight is always between 2 road nodes. Some nodes were selected on the walls of the chapel, for which were explicitly calculated the displacements and the accelerations. When the vehicle is near the chapel wall, the displacements begin to increase up to the point that the wall reaches its maximum displacement. Some nonlinear graphs of normal and shear stresses variations were determined for the operating weight of a large hydraulic excavator on tracks as heavy circulating vehicle. Although the chapel structure might look safe for ultimate limit conditions that apparently do not reach critical stress values, the chapel behaviour indicates indexes and conditions which imply reduction or loss of serviceability. The peak sway ratios for this chapel under heavy traffic reached values only characteristic of much slender structures like masonry bell towers (Selby and Wilson [3]). Also, the calculated peak transient horizontal accelerations for several nodes on the west wall, far exceeded the peak recommended value of 42 mm/s2 defined in BS 6472 [4] for adverse human exposure to vibration in buildings. (Paper 140)
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-07-23 às 13:32:41 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico