Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Long-term results after standard endovascular aneurysm repair with the Endurant and Excluder stent grafts

Long-term results after standard endovascular aneurysm repair with the Endurant and Excluder stent grafts

Título
Long-term results after standard endovascular aneurysm repair with the Endurant and Excluder stent grafts
Tipo
Artigo em Revista Científica Internacional
Ano
2020
Autores
Oliveira Pinto, J
(Autor)
FMUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Oliveira, NFG
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Bastos Goncalves, FM
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Hoeks, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Van Rijn, MJ
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ten Raa, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Mansilha A.
(Autor)
FMUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Verhagen, HJM
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 71
Páginas: 64-74
ISSN: 0741-5214
Editora: Elsevier
Outras Informações
ID Authenticus: P-00Q-MP2
Abstract (EN): Objective: Many endografts are currently available for standard endovascular repair of infrarenal abdominal aortic aneurysms. Comparison of long-term outcomes between devices might aid in this decision process, but comparative data are scarce. The purpose of this study was to report long-term clinical outcomes of two commercially available endoprosthesis, the Endurant (Medtronic Vascular, Inc, Minneapolis, Minn) and the Excluder (W. L. Gore & Associates, Flagstaff, Ariz) stent grafts. Methods: Patients undergoing standard endovascular repair from July 2004 to December 2011 in a single institution with the Endurant or the Low-Porosity Excluder endografts were eligible. Only patients treated for intact degenerative abdominal infrarenal aneurysms were included. All measurements were performed on center-lumen line reconstructions obtained on dedicated software. The primary end point was primary clinical success, defined as clinical success without the need for an additional or secondary surgical or endovascular procedure. Neck-related events (a composite of type IA endoleak, neck-related secondary intervention, or migration of >5 mm), neck morphology changes, renal function, and overall survival were secondary end points. Results: The study included 277 patients (156 Endurants; 121 Excluders). The median follow-up was 5.8 years (range, 0.1-12.4 years) and did not differ between groups (P = .18). Patients treated with the Endurant stent graft had wider (neck diameter of >28 mm, 27.3% vs 1.7% [P < .001]; neck diameter of 27 mm, [interquartile range (IQR), 24-29 mm] for Endurant and 24mm[IQR, 22-25 mm] for Excluder; P < .001) and more angulated necks (beta-angle of >60 degrees, 26.7% vs 12.5%; P = .004). Oversizing was greater in the Endurant group (16% [IQR, 12%-22%] vs 13% [IQR, 8%-17%], respectively; P < .001). Patients were treated outside device instructions for use regarding proximal neck: 16.7% in the Endurant and 17.3% in the Excluder group (P = .720). The 7-year primary clinical success was 54.7% for the Endurant and 58.1% for the Excluder groups (P = .53). Freedom from neck-related events at 7 years was 76.7% for the Endurant and 78.8% for Excluder group (P = .94). The Endurant stent graft (hazard ratio [HR], 2.7; 95% confidence interval [CI], 1.3-5.8; P = .009) was an independent predictor of significant renal function decline. Neck dilatation was greater in Endurant-implanted patients (13% [95% CI, 2%-22%] vs 4% [95% CI, 0%-10%]; P < .001). Overall survival at 7 years was 61.4% in the Endurant and 50.3% (n = 50; standard error, 0.047) in the Excluder group (P = .39). Conclusions: This study reveals that durable and sustainable results can be obtained with either of these late generation devices. This finding suggests that careful planning and a tailored device selection taking into account the patient's anatomy are more relevant determinants than the graft model itself to obtain clinical success. The Endurant endoprosthesis seems to be associated with a higher rate of neck dilatation and faster decrease in the estimated glomerular filtration rate, but further studies with longer follow-up are necessary to determine the clinical relevance of these findings.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 11
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Two-Stage Covered Endovascular Reconstruction of Aortic Bifurcation (CERAB) for Patients With Chronic Limb-Threatening Ischemia (2024)
Outra Publicação em Revista Científica Internacional
Zydlewski, P; Hendiger, W; Rocha Neves, J; Kruszyna, ¿; Taranta, I
The effect of the collateral cerebrovascular circulation on tolerance to carotid artery cross-clamping and on early outcome after carotid endarterectomy (2024)
Outra Publicação em Revista Científica Internacional
Myrcha, P; Pinheiro, F; Rocha Neves, J; Myrcha, J; Gloviczki, P
Strengths and obvious limitations of transcervical carotid artery revascularization (2021)
Outra Publicação em Revista Científica Internacional
Coelho, AP; de Borst, GJ
Open aortic reconstruction for middle aortic syndrome associated with right renal artery poststenotic aneurysm (2022)
Outra Publicação em Revista Científica Internacional
Tenorio E.R.; Dias-Neto M; Ocasio L.; Macedo T.A.; Oderich G.S.
Management and outcomes of a vascular surgery department with sudden medical staff outbreak of COVID-19 (2020)
Outra Publicação em Revista Científica Internacional
Pereira Neves, A; Rocha Neves, J; Cerqueira, A; Teixeira, J

Ver todas (19)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-10-04 às 14:16:23 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico