Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis

Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis

Título
Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis
Tipo
Artigo em Revista Científica Internacional
Ano
2021
Autores
Hassan, C
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Spadaccini, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Iannone, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Maselli, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Jovani, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Chandrasekar, VT
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Antonelli, G
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Yu, HG
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Areia, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Bhandari, P
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Sharma, P
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Rex, DK
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Rosch, T
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Wallace, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Repici, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 93
Páginas: 77-+
ISSN: 0016-5107
Editora: Elsevier
Outras Informações
ID Authenticus: P-00S-XEB
Abstract (EN): Background and Aims: One-fourth of colorectal neoplasia are missed at screening colonoscopy, representing the main cause of interval colorectal cancer. Deep learning systems with real-time computer-aided polyp detection (CADe) showed high accuracy in artificial settings, and preliminary randomized controlled trials (RCTs) reported favorable outcomes in the clinical setting. The aim of this meta-analysis was to summarize available RCTs on the performance of CADe systems in colorectal neoplasia detection. Methods: We searched MEDLINE, EMBASE, and Cochrane Central databases until March 2020 for RCTs reporting diagnostic accuracy of CADe systems in the detection of colorectal neoplasia. The primary outcome was pooled adenoma detection rate (ADR), and secondary outcomes were adenoma per colonoscopy (APC) according to size, morphology, and location; advanced APC; polyp detection rate; polyps per colonoscopy; and sessile serrated lesions per colonoscopy. We calculated risk ratios (RRs), performed subgroup and sensitivity analyses, and assessed heterogeneity and publication bias. Results: Overall, 5 randomized controlled trials (4354 patients) were included in the final analysis. Pooled ADR was significantly higher in the CADe group than in the control group (791/2163 [ 36.6%] vs 558/2191 [ 25.2%]; RR, 1.44; 95% confidence interval [CI], 1.27-1.62; P<.01; I-2 = 42%). APC was also higher in the CADe group compared with control (1249/2163 [.58] vs 779/2191 [.36]; RR, 1.70; 95% CI, 1.53-1.89; P < .01; I-2 = 33%). APC was higher for <= 5-mm (RR, 1.69; 95% CI, 1.48-1.84), 6- to 9-mm (RR, 1.44; 95% CI, 1.19-1.75), and >= 10-mm adenomas (RR, 1.46; 95% CI, 1.04-2.06) and for proximal (RR, 1.59; 95% CI, 1.34-1.88), distal (RR, 1.68; 95% CI, 1.50-1.88), flat (RR, 1.78; 95% CI, 1.47-2.15), and polypoid morphology (RR, 1.54; 95% CI, 1.40-1.68). Regarding histology, CADe resulted in a higher sessile serrated lesion per colonoscopy (RR, 1.52; 95% CI, 1.14-2.02), whereas a nonsignificant trend for advanced ADR was found (RR, 1.35; 95% CI,.74-2.47; P = .33; I-2 = 69%). Level of evidence for RCTs was graded as moderate. Conclusions: According to available evidence, the incorporation of artificial intelligence as aid for detection of colorectal neoplasia results in a significant increase in the detection of colorectal neoplasia, and such effect is independent from main adenoma characteristics.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 15
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Unusual cause for upper GI bleeding: a splenic artery aneurysm mimicking a Dieulafoy lesion. Role for systematic EUS assessment? (2010)
Outra Publicação em Revista Científica Internacional
Pinto Marques, P; Giria, J; Brito, M; Camacho, R; Loureiro, R
Ulcerative esophagitis caused by etidronate (2001)
Outra Publicação em Revista Científica Internacional
Macedo G; Azevedo, F; Ribeiro, T
Through-the-needle biopsy sampling may allow preoperative intraductal papillary mucinous neoplasia subtyping (2020)
Outra Publicação em Revista Científica Internacional
Vilas Boas, F; Costa Moreira, P; Moutinho Ribeiro, P; Martins, D; Lopes, J; Macedo G
There is no clinical evidence of consequences after methylene blue chromoendoscopy (2008)
Outra Publicação em Revista Científica Internacional
Mario Dinis Ribeiro; Moreira Dias, L
The natural history of steroid-naive eosinophilic esophagitis: the other end of the spectrum (2015)
Outra Publicação em Revista Científica Internacional
Rodrigues Pinto, E; Pereira, P; Macedo G

Ver todas (55)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-26 às 00:16:14 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico