Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Agreement and accuracy using the FIGO, ACOG and NICE cardiotocography interpretation guidelines

Agreement and accuracy using the FIGO, ACOG and NICE cardiotocography interpretation guidelines

Título
Agreement and accuracy using the FIGO, ACOG and NICE cardiotocography interpretation guidelines
Tipo
Artigo em Revista Científica Internacional
Ano
2017
Autores
Santo, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Diogo Ayres de Campos
(Autor)
FMUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Schnettler, W
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ugwumadu, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Da Graca, LM
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 96
Páginas: 166-175
ISSN: 0001-6349
Editora: Wiley-Blackwell
Outras Informações
ID Authenticus: P-00M-GKY
Abstract (EN): IntroductionOne of the limitations reported with cardiotocography is the modest interobserver agreement observed in tracing interpretation. This study compared agreement, reliability and accuracy of cardiotocography interpretation using the International Federation of Gynecology and Obstetrics, American College of Obstetrics and Gynecology and National Institute for Health and Care Excellence guidelines. Material and methodsA total of 151 tracings were evaluated by 27 clinicians from three centers where International Federation of Gynecology and Obstetrics, American College of Obstetrics and Gynecology and National Institute for Health and Care Excellence guidelines were routinely used. Interobserver agreement was evaluated using the proportions of agreement and reliability with the statistic. The accuracy of tracings classified as pathological/category III was assessed for prediction of newborn acidemia. For all measures, 95% confidence interval were calculated. ResultsCardiotocography classifications were more distributed with International Federation of Gynecology and Obstetrics (9, 52, 39%) and National Institute for Health and Care Excellence (30, 33, 37%) than with American College of Obstetrics and Gynecology (13, 81, 6%). The category with the highest agreement was American College of Obstetrics and Gynecology category II (proportions of agreement = 0.73, 95% confidence interval 0.70-76), and the ones with the lowest agreement were American College of Obstetrics and Gynecology categories I and III. Reliability was significantly higher with International Federation of Gynecology and Obstetrics ( = 0.37, 95% confidence interval 0.31-0.43), and National Institute for Health and Care Excellence ( = 0.33, 95% confidence interval 0.28-0.39) than with American College of Obstetrics and Gynecology ( = 0.15, 95% confidence interval 0.10-0.21); however, all represent only slight/fair reliability. International Federation of Gynecology and Obstetrics and National Institute for Health and Care Excellence showed a trend towards higher sensitivities in prediction of newborn acidemia (89 and 97%, respectively) than American College of Obstetrics and Gynecology (32%), but the latter achieved a significantly higher specificity (95%). ConclusionsWith American College of Obstetrics and Gynecology guidelines there is high agreement in category II, low reliability, low sensitivity and high specificity in prediction of acidemia. With International Federation of Gynecology and Obstetrics and National Institute for Health and Care Excellence guidelines there is higher reliability, a trend towards higher sensitivity, and lower specificity in prediction of acidemia.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 10
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Maternal heart rate analysis during labor. Has the time come for computerized analysis? (2012)
Outra Publicação em Revista Científica Internacional
Joao Bernardes; Diogo Ayres de Campos
Interobserver agreement according to STAN guidelines (2008)
Outra Publicação em Revista Científica Internacional
Costa Santos C; Bernardes J
Electronic fetal monitoring: What's reassuring? (multiple letters) [1] (1999)
Outra Publicação em Revista Científica Internacional
Joao Bernardes; Berkus, MD
Electronic fetal monitoring: what's reassuring? (1999)
Outra Publicação em Revista Científica Internacional
Joao Bernardes

Ver todas (20)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-17 às 07:15:57 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico