ECG artefact detection algorithm: An algorithm to improve long-term ECG analysis

Título
ECG artefact detection algorithm: An algorithm to improve long-term ECG analysis
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
2012
Autores
Bras, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ferreira, N
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ata de Conferência Internacional
Páginas: 329-333
International Conference on Bio-inspired Systems and Signal Processing, BIOSIGNALS 2012
Vilamoura, Algarve, 1 February 2012 through 4 February 2012
Indexação
Outras Informações
ID Authenticus: P-008-471
Abstract (EN): Newly devices allow the analysis and collection of very long-term electrocardiogram (ECG). However, associated with this devices and long-term signal, are artefacts that conduce to misleading interpretations and diagnosis. So, new developments over automatic ECG classification are needed for a reliable interpretation. The feasibility of the cardiac systems is one of the main concerns, once they are currently used as diagnosis or help systems. In this project, an artefact detection algorithm is developed, dividing the time-series in intervals of signal and artefact. The algorithm is based on the assumption that, if the analysed frame is signal, there is not an abrupt alteration over consecutive short windows. So, the time-series is divided in consecutive nonoverlapped short windows. Over these windows, it is calculated the time-series standard deviation, the maximum and minimum slope. A threshold-based rule is applied, and the algorithm reveals that, in mean, it is verified a 99.29% of correctly classified signal and only 0.71% of signal erroneously classified. Over the results obtained, the algorithm seems to present good results, however it is needed its validation in a wider and representative sample with segments marked as artefact by multiple specialists.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-12-06 às 23:17:29 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico