Saltar para:
Logótipo
Você está em: Início > Publicações > Visualização > Construction and evaluation of ion selective electrodes for perchlorate with a summing operational amplifier: application to pyrotechnics mixtures analysis

Construction and evaluation of ion selective electrodes for perchlorate with a summing operational amplifier: application to pyrotechnics mixtures analysis

Título
Construction and evaluation of ion selective electrodes for perchlorate with a summing operational amplifier: application to pyrotechnics mixtures analysis
Tipo
Artigo em Revista Científica Internacional
Ano
1999
Autores
Perez Olmos, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Rios, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Martin, MP
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Título: The AnalystImportada do Authenticus Pesquisar Publicações da Revista
Vol. 124
Páginas: 97-100
ISSN: 0003-2654
Outras Informações
ID Authenticus: P-001-5BB
Abstract (EN): The construction and evaluation of an electrode selective to perchlorate with improved sensitivity, constructed like a conventional electrode (ISE), but using an operational amplifier to sum the potentials supplied by four membranes (ESOA) is described. The two types of electrodes, without an inner reference solution, were constructed using octylammonium chloride as sensor, a mixture of dibutylphthalate and o-nitrophenyloctyl ether as solvent mediator and PVC as plastic matrix, the membranes being obtained by direct application onto a conductive epoxy resin support. After the comparative evaluation of their working characteristics they were used in the determination of perchlorate in propellants, fulminating powders and fireworks. On all occasions, the results obtained by the ESOA were found to be similar to those obtained by the conventional ISE, but with higher precision. The limit of detection of the direct potentiometric method developed was found to be 0.1 g kg(-1), and the precision and accuracy of the method, when applied to eight different samples of pyrotechnic mixtures, expressed in terms of mean relative standard deviation and average percentage of spike recovery were 0.4% and 100.5%, respectively. Adequate agreement was found between the results obtained by the potentiometric method and the reference methods, since the calculated relative errors ranged from +0.4% to -0.5%.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 4
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

The role of ionic liquids in the biocatalytic evaluation of bisphenol levels as contaminant: an automatic approach (2018)
Artigo em Revista Científica Internacional
Costa, AR; Passos, MLC; Pinto, PCAG; Pereira, SAP; Lucia L M F S Saraiva
Stochastic detection and characterisation of individual ferrocene derivative tagged graphene nanoplatelets (2016)
Artigo em Revista Científica Internacional
Wu, HY; Lin, QW; Batchelor McAuley, C; Goncalves, LM; Lima, CFRAC; Compton, RG

Ver todas (47)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-20 às 06:49:45 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico