Improvement of the methods for skin mechanical properties evaluation through correlation between different techniques and factor analysis

Título
Improvement of the methods for skin mechanical properties evaluation through correlation between different techniques and factor analysis
Tipo
Artigo em Revista Científica Internacional
Ano
2013
Autores
neto, p
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
ferreira, m
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
bahia, f
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
costa, p
(Autor)
FFUP
Revista
Vol. 19
Páginas: 405-416
ISSN: 0909-752X
Editora: Wiley-Blackwell
Outras Informações
ID Authenticus: P-006-6DT
Abstract (EN): BackgroundIn the past decades, many instruments have been developed to measure skin elasticity and firmness. The offer is extensive and is constantly increasing, becoming difficult to decide which equipment and mechanical property measurement are better to portrait the desired characteristics. The aim of this study was to compare and correlate parameters assessed with different probes, based on different methodologies, to understand which probe characterizes each skin elasticity property. MethodsMeasurements were performed in the abdomen region of 34 female volunteers, with three different probes: Cutometer((R)) SEM575, Reviscometer((R)) RVM600 and Frictiometer((R)) FR700. Statistical data analysis was performed by Factor Analysis on IBM SPSS Statistics 17.0. ResultsFrictiometer((R)) and Reviscometer((R)) measurements showed significant correlations with Cutometer's Uf, Ua, Ur and Ue parameters. Ue was strongly and significantly correlated to Uf and Ur. Ua was strongly and significantly correlated with Ur, Uf and Ue. Reviscometer((R)) measurements were similar along the same axis, and measurements performed in a specific direction are significantly correlated with age. ConclusionA simpler and faster methodology for the complete assessment of elasticity and firmness of human skin is possible, in alternative to elaborate and time consuming methods, involving several equipments and parameters. The simpler methodology does not reduce the information obtained about the skin properties.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Contacto: marta.ferreira@inovapotek.com
Nº de páginas: 12
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

The role of AI classifiers in skin cancer images (2019)
Artigo em Revista Científica Internacional
Carolina Magalhães; Joaquim Mendes; Ricardo Vardasca
Recent use of medical infrared thermography in skin neoplasms (2018)
Artigo em Revista Científica Internacional
C. Magalhães; Ricardo Vardasca; Joaquim Mendes
Efficacy of anti-wrinkle products in skin surface appearance: a comparative study using non-invasive methods (2010)
Artigo em Revista Científica Internacional
ferreira, mr; costa, pc; bahia, fm
Recomendar Página Voltar ao Topo