Abstract (EN):
Evaluating diffusion properties of novel optical clearing (OC) agents is critical for advancing medical imaging. Tartrazine (TTZ), a strong absorbing dye, has shown promise in enhancing tissue transparency, yet its diffusion properties remain uncharacterized. In this work, OC treatments with TTZ-water solutions with varying osmolarities were performed, and the diffusion times (tau) that characterize the tissue dehydration and the RI matching mechanisms were estimated. From kinetic T-c measurements during treatment, tau values of water and TTZ were estimated in muscles as 60.0 s and 416.0 s, respectively. Corresponding diffusion coefficients (D) were derived from sample thickness data measured during treatments where the unique fluxes of TTZ and water occur. The respective D values were then calculated as 1.9 x 10(-6) cm(2)/s for water and 3.6 x 10(-7) cm(2)/s for TTZ. These findings provide key insights into TTZ diffusion in skeletal muscle and support its potential as an effective OC agent.
Idioma:
Inglês
Tipo (Avaliação Docente):
Científica
Nº de páginas:
8