Go to:
Logótipo
Você está em: Start > Publications > View > SURFACE CHANGES (SCANNING ELECTRON MICROSCOPE) INDUCED BY ARTIFICIAL SALIVA IN TITANIUM-MOLYBDENUM ORTHODONTIC LOOPS
Publication

SURFACE CHANGES (SCANNING ELECTRON MICROSCOPE) INDUCED BY ARTIFICIAL SALIVA IN TITANIUM-MOLYBDENUM ORTHODONTIC LOOPS

Title
SURFACE CHANGES (SCANNING ELECTRON MICROSCOPE) INDUCED BY ARTIFICIAL SALIVA IN TITANIUM-MOLYBDENUM ORTHODONTIC LOOPS
Type
Article in International Conference Proceedings Book
Year
2018
Authors
Castro, S
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Maria João Ponces
(Author)
FMDUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Reis Campos, JCR
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lopes, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pollmann, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Pages: 1429-1430
Proceedings IRF2018: 6th International Conference I ntegrity-Reliability-Failure
Lisbon, Portugal, 22-26 July 2018
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Other information
Authenticus ID: P-00Q-XG6
Abstract (EN): This work, intended to assess the effect of saliva pH (4 and 6,75) at different times (3 and 5 months) using a descriptive analysis of the microtopography (scanning electron microscope, (SEM)) of a commercial titanium-molybdenum alloy (TMA, Ormco Corp, Glendora, Calif) with a 0,017 '' x 0,025 '' section. SEM analysis was carried out at Materials Centre of the University of Porto (CEMUP) and micrographs with x2000 and x5000 magnification were obtained using a JEOL JSM 6301F high resolution.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 2
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2026 © Faculdade de Farmácia da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2026-02-26 at 09:46:07 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book