Go to:
Logótipo
Você está em: Start > Publications > View > Thermal performance of a PCM firefighting suit considering transient periods of fire exposure, post - fire exposure and resting phases
Publication

Thermal performance of a PCM firefighting suit considering transient periods of fire exposure, post - fire exposure and resting phases

Title
Thermal performance of a PCM firefighting suit considering transient periods of fire exposure, post - fire exposure and resting phases
Type
Article in International Scientific Journal
Year
2021-07-20
Authors
Jorge A. Fonseca
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications Without AUTHENTICUS View ORCID page
Journal
Vol. 182
Pages: 1-11
ISSN: 1359-4311
Publisher: Elsevier
Other information
Authenticus ID: P-00S-W0B
Resumo (PT):
Abstract (EN): Firefighting scenarios may be characterized by various transient periods (i.e. phases), which consist of diverse environmental conditions. Firefighters usually encounter fire exposure, post fire exposure and resting phases. Development of new and improved protective clothing must be able to provide protection throughout all these phases, as burnouts may still occur after fire exposure due to accumulation of heat in the garment. The incorporation of phase change materials (PCMs) in firefighting garments has been shown to minimize the potential of heat hazards only during fire exposure. Thus to get more knowledge on their thermal performance, in the present study, the effect of PCM incorporation in post fire and resting phases were also numerically studied. The numerical code was validated for all phases. Five potential PCM candidates were considered. Exposure phases were characterized by high- medium and low- heat flux intensities (84, 12 and 5 kW.m(-2)) with variable exposure times whilst post -exposure and resting phases where characterized by different wind speeds (i.e. ambient convective coefficients). Optimal PCM masses, times to second and third - degree burns as well as PCM suit cooling times were calculated to reflect thermal protective performance in each respective phase. The data generated allows for PCM short-listing from a set of potential PCM candidates along with its geometrical parameters, considering a wide range of characteristics of the various phases that consist a typical firefighting scenario.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 11
Documents
File name Description Size
preprintmanuscript Pre print manuscript 1341.38 KB
Related Publications

Of the same authors

DIF-Jacket – Development of an innovative firefighter jacket (2022)
Poster in an International Conference
F. Marques; J. Ribeiro; R. Pereira; M. Silva; G. Santos; L. Valente; A. Fonseca; Miranda, JM; Campos, JBLM; Soraia Neves

Of the same journal

“Recent Advances in Building Air Conditioning Systems for Buildings”. (2006)
Article in International Scientific Journal
Afonso, C.F.A.
Ventilation terminals for use with light pipes in buildings: a CFD study (2000)
Article in International Scientific Journal
Szabolcs Varga; Armando C. Oliveira
Ventilation Terminals For Use With Light Pipes In Buildings (2000)
Article in International Scientific Journal
Szabolcs Varga; Armando C. Oliveira
Thermal performance of a novel air conditioning system using a liquid desiccant (2000)
Article in International Scientific Journal
Armando C. Oliveira; Clito F. Afonso; Saffa B. Riffat; Prince S. Doherty
Thermal behaviour of closed wet cooling towers for use with chilled ceilings (2000)
Article in International Scientific Journal
Jorge Facao; Armando C. Oliveira

See all (30)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Farmácia da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2025-06-17 at 17:26:18 | Acceptable Use Policy | Data Protection Policy | Complaint Portal