Abstract (EN):
A method to detect juxta-pleural nodules with radius smaller than 5mm is presented. The intensity difference between nodules and parenchymal tissue as well as the nodules' natural roundness are exploited. Solid nodules are detected by selecting an appropriate threshold over a sliding window, whereas sub-solid/non-solid nodules are enhanced using multi-scale Laplacian-of-Gaussian filters. The 2D-wise outputs are combined to 3D, producing a final candidate list. False positive reduction is achieved with fixed rules and supervised learning. The achieved sensitivity is 57% with 4 false positives/scan, increasing to 62% if only solid nodules are considered. © 2017 SPIE.
Idioma:
Inglês
Tipo (Avaliação Docente):
Científica