Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Logótipo
Você está em: Início > Publicações > Visualização > Automatic Multipumping Flow System for Handling Viscous Solutions: Application to the Spectrophotometric Determination of Trimipramine

Automatic Multipumping Flow System for Handling Viscous Solutions: Application to the Spectrophotometric Determination of Trimipramine

Título
Automatic Multipumping Flow System for Handling Viscous Solutions: Application to the Spectrophotometric Determination of Trimipramine
Tipo
Artigo em Revista Científica Internacional
Ano
2008
Autores
David S. M. Ribeiro
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Joao A. V. Prior
(Autor)
FFUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Joao L. M. Santos
(Autor)
FFUP
Revista
Título: Analytical LettersImportada do Authenticus Pesquisar Publicações da Revista
Vol. 41 10
Páginas: 2684-2696
ISSN: 0003-2719
Editora: Taylor & Francis
Indexação
Classificação Científica
FOS: Ciências exactas e naturais > Química
CORDIS: Ciências da Saúde
Outras Informações
ID Authenticus: P-004-2GR
Resumo (PT): The present work describes the implementation, by using MultiPumping Flow Analysis System (MPFS), of a spectrophotometric method for the determination of trimipramine in commercially available pharmaceutical formulations, based on the reaction with ammonium monovanadate in acidic medium yielding a colored compound with a maximum of absorbance at 620 nm. The improved flow mixing conditions during sample and reagents insertion and transport, as a result of the chaotic movement of the solutions originated by the MPFS pulsed flow, assured a fast reaction zone homogenization in a reduced residence time, which was particularly advantageous for carrying out analytical determinations that involved highly viscous solutions, as is the case of the sulfuric acid solution used in the determination of trimipramine, without impairing the sampling rate. A linear working range for trimipramine concentrations of up to 50 mg L-1 (r = 0.9998; n = 6) was obtained, and the determined detection limit was about 1.15 mg L-1. The sampling rate was approximately 50 determinations per hour. The obtained results were in agreement with those furnished by the reference procedure, with relative deviations lower than 4.7%. With the developed MPFS, the consumption of the reagents ammonium monovanadate and sulfuric acid was reduced by approximately 41.02% and 54.29%, respectively, compared with a previously proposed multicommutated flow analysis system. <br> <br> Keywords: Flow analysis; multipumping; pulsed flow; trimipramine; viscous solutions <br> <a target="_blank" href="http://www.informaworld.com/smpp/content~db=all~content=a905129086"> texto integral </a> <br> <br>
Abstract (EN): The present work describes the implementation, by using MultiPumping Flow Analysis System (MPFS), of a spectrophotometric method for the determination of trimipramine in commercially available pharmaceutical formulations, based on the reaction with ammonium monovanadate in acidic medium yielding a colored compound with a maximum of absorbance at 620nm. The improved flow mixing conditions during sample and reagents insertion and transport, as a result of the chaotic movement of the solutions originated by the MPFS pulsed flow, assured a fast reaction zone homogenization in a reduced residence time, which was particularly advantageous for carrying out analytical determinations that involved highly viscous solutions, as is the case of the sulfuric acid solution used in the determination of trimipramine, without impairing the sampling rate. A linear working range for trimipramine concentrations of up to 50mgL-1 (r=0.9998; n=6) was obtained, and the determined detection limit was about 1.15mgL-1. The sampling rate was approximately 50 determinations per hour. The obtained results were in agreement with those furnished by the reference procedure, with relative deviations lower than 4.7%. With the developed MPFS, the consumption of the reagents ammonium monovanadate and sulfuric acid was reduced by approximately 41.02% and 54.29%, respectively, compared with a previously proposed multicommutated flow analysis system.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 13
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Das mesmas áreas científicas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster em Conferência Nacional
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Outra Publicação em Revista Científica Internacional
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Outra Publicação em Revista Científica Internacional
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Outra Publicação em Revista Científica Internacional
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM

Ver todas (159)

Da mesma revista

Electrochemical methods in pesticides control (2004)
Outra Publicação em Revista Científica Internacional
Garrido, EM; Delerue Matos, C; Lima, JLFC; Brett, AMO
Use and Reuse of SPE Disks for the Determination of Pyrethroids in Water by GC-ECD (2009)
Artigo em Revista Científica Internacional
Valentina Domingues; Miguel Cabral; Arminda Alves; Cristina Delerue Matos
Square-Wave Adsorptive-Stripping Voltammetric Detection in the Quality Control of Fluoxetine (2007)
Artigo em Revista Científica Internacional
Henri P. A. Nouws; Cristina Delerue-Matos; Aquiles A. Barros; Jose´ A. Rodrigues; Alice Santos-Silva; Fernanda Borges
Square-wave adsorptive-stripping voltammetric detection in the quality control of fluoxetine (2007)
Artigo em Revista Científica Internacional
Henri P A Nouws; Cristina Delerue Matos; Aquiles A Barros; Jose A Rodrigues; Alice Santos Silva; Fernanda Borges
Spectrophotometric Determination of Bromate in Water Using Multisyringe Flow Injection Analysis (2011)
Artigo em Revista Científica Internacional
Sara M Oliveira; Marcela A Segundo; Antonio O S S Rangel; Jose L F C Lima; Victor Cerda

Ver todas (33)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Psicologia e de Ciências da Educação da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-11-25 às 08:14:52 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico