Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Logótipo
Você está em: Start > Publications > View > On-plate digestion using a commercial microfraction collector for nano-HPLC matrix-assisted laser desorption/ionization tandem time-of-flight protein analysis
Publication

On-plate digestion using a commercial microfraction collector for nano-HPLC matrix-assisted laser desorption/ionization tandem time-of-flight protein analysis

Title
On-plate digestion using a commercial microfraction collector for nano-HPLC matrix-assisted laser desorption/ionization tandem time-of-flight protein analysis
Type
Another Publication in an International Scientific Journal
Year
2008
Authors
vitorino, r
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
guedes, s
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
tomer, k
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
domingues, p
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
amado, f
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 380 No. 1
Pages: 128-130
ISSN: 0003-2697
Publisher: Elsevier
Scientific classification
FOS: Natural sciences > Biological sciences
Other information
Authenticus ID: P-003-WAK
Abstract (EN): A new method for on-plate protein digestion and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry analysis is proposed involving an automated one-step sample separation using nano-flow HPLC followed by nanoliter fraction collection and on-plate digestion with trypsin. This procedure uses a commercial automatic nanoliter fraction collection system for on-line spotting of the eluent onto a MALDI target. After protein digestion, the reaction is stopped by the addition of acidified matrix using the same automated system. Collected spots are subsequently analyzed using a MALDI tandem time-of-flight (TOF/TOF) mass spectrometer for protein sequencing and identification.
Language: English
Type (Professor's evaluation): Scientific
Contact: rvitorino@ua.pt
No. of pages: 3
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Quantification of alpha-lactalbumin in human milk: Method validation and application (2007)
Another Publication in an International Scientific Journal
Lucia H L M L M Santos; Isabel M P L V O Ferreira
A method for functional mouse MDR3 P-glycoprotein reconstitution in Escherichia coli lipids (2005)
Another Publication in an International Scientific Journal
Lima, SAC; Cordeiro da Silva, A; Gameiro, P; de Castro, B
Subcellular proteomics of mice gastrocnemius and soleus muscles (2007)
Article in International Scientific Journal
vitorino, r; ferreira, r; neuparth, m; guedes, s; williams, j; tomer, kb; domingues, pm; appell, hj; duarte, ja; amado, fml
Semiautomated computer-assisted image analysis to quantify 3,3 '-diaminobenzidine tetrahydrochloride-immuno stained small tissues (2006)
Article in International Scientific Journal
Sandra Leal; Carmen Diniz; Carlos Sa; Jorge Goncalves; Ana Sofia Soares; Carolina Rocha Pereira; Paula Fresco
Quartz crystal microbalance as a tool for kinetic enzymatic assays by variation of pH (2011)
Article in International Scientific Journal
dos santos, fc; goncalves, lm; riccardi, cd; barros, aa; bueno, pr

See all (19)