Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Logótipo
Você está em: Start > Publications > View > Gran method for end point anticipation in monosegmented flow titration
Publication

Gran method for end point anticipation in monosegmented flow titration

Title
Gran method for end point anticipation in monosegmented flow titration
Type
Article in International Scientific Journal
Year
2004
Authors
Aquino, EV
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pasquini, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rohwedder, JJR
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Raimundo, IM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Montenegro, MCBSM
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Araujo, AN
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 15
Pages: 111-115
ISSN: 0103-5053
Indexing
Scientific classification
FOS: Natural sciences > Chemical sciences
CORDIS: Health sciences
Other information
Authenticus ID: P-000-D4B
Resumo (PT): Este trabalho descreve o uso do método de linearização de Gran em titulações em fluxo monossegmentado com detecção potenciométrica. O programa de controle pode estimar o ponto final após a adição de três ou quatro alíquotas de titulante. Alternativamente, o ponto final da titulação pode ser determinado pelo método da segunda derivada. Neste caso, alíquotas adicionais de titulante são adicionadas até a proximidade do ponto final e três pontos antes e após o ponto estequiométrico são usados para o cálculo de ponto final. O desempenho do sistema foi avaliado pela determinação de cloreto em soluções isotônicas e parenterais. O sistema emprega um eletrodo indicador tubular de Ag2S/AgCl. Uma titulação típica, realizada de acordo com a definição IUPAC, requer apenas 60 μL de amostra e aproximadamente o mesmo volume de titulante (AgNO3). Uma titulação completa pode ser realizada entre 1 e 5 min. Foram obtidas exatidão e precisão (desvio padrão relativo de 10 replicatas) de 2% e 1% para o método de Gran e 1% e 0,5% para o método de Gran associado ao método da segunda derivada, respectivamente. O sistema proposto reduz o tempo para realizar uma titulação, com baixo consumo de amostra e reagente, além de possibilitar uma amostragem automática completa e adição de titulante sem a necessidade de uma etapa de calibração <br> <br> Keywords: monosegmented flow analysis, Gran method, chloride titration <br> <a href="http://jbcs.sbq.org.br/jbcs/2004/vol15_n1/16-002-04.pdf"> Texto integral</a> <br> <br>
Abstract (EN): An automatic potentiometric monosegmented flow titration procedure based on Gran linearisation approach has been developed. The controlling program can estimate the end point of the titration after the addition of three or four aliquots of titrant. Alternatively, the end point can be determined by the second derivative procedure. In this case, additional volumes of titrant are added until the vicinity of the end point and three points before and after the stoichiometric point are used for end point calculation. The performance of the system was assessed by the determination of chloride in isotonic beverages and parenteral solutions. The system employs a tubular Ag2S/AgCl indicator electrode. A typical titration, performed according to the IUPAC definition, requires only 60 muL of sample and about the same volume of titrant ( AgNO3) solution. A complete titration can be carried out in 1 - 5 min. The accuracy and precision ( relative standard deviation of ten replicates) are 2% and 1% for the Gran and 1% and 0.5% for the Gran/derivative end point determination procedures, respectively. The proposed system reduces the time to perform a titration, ensuring low sample and reagent consumption, and full automatic sampling and titrant addition in a calibration-free titration protocol.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same scientific areas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster in a National Conference
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Another Publication in an International Scientific Journal
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Another Publication in an International Scientific Journal
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Another Publication in an International Scientific Journal
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM
Volatile composition of Catharanthus roseus (L.) G. Don using solid-phase microextraction and gas chromatography/mass spectrometry (2009)
Article in International Scientific Journal
De Pinho, PG; Rui F Goncalves; Patricia Valentao; David M Pereira; Rosa M Seabra; Paula B Andrade; Mariana Sottomayor

See all (159)

Of the same journal

Uncertainty in the Determination of Glucose and Sucrose in Solutions with Chitosan by Enzymatic Methods (2013)
Article in International Scientific Journal
Berta Nogueiro Estevinho; Amélia Ferraz; Lúcia Silveira Santos; Fernando Rocha; Arminda Alves
Sequential injection analysis determination of sulphate in wastewaters by ultraviolet-spectrophotometry (2000)
Article in International Scientific Journal
Lapa, RAS; Lima, JLFC; Pinto, IVOS
Pyranoflavylium Derivatives Extracted from Wine Grape as Photosensitizers in Solar Cells (2014)
Article in International Scientific Journal
Christiane M. Santos; Bárbara Gomes; Luís M. Gonçalves; Joana Oliveira; Sandra Rocha; Manuel Coelho; José A. Rodrigues; Victor Freitas; Helena Aguilar
Production of Chloride and Hypochlorite for Analytical Purposes by Sonochemical Degradation of Organochlorines (2005)
Article in International Scientific Journal
Mauro Korn; Maria Soledad M. S. F. Acevedo; Sivanildo S. Borges; Jose L. F. C. Lima

See all (17)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Psicologia e de Ciências da Educação da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-11-12 at 11:44:18 | Acceptable Use Policy | Data Protection Policy | Complaint Portal