Você está em: Start > Publications > View > Analysis and Monitoring of the Drying Process of a Hygro-Regulated Wall Base Ventilation System Implemented in a Historical Church to Control Rising Damp
Publication

Analysis and Monitoring of the Drying Process of a Hygro-Regulated Wall Base Ventilation System Implemented in a Historical Church to Control Rising Damp

Title
Analysis and Monitoring of the Drying Process of a Hygro-Regulated Wall Base Ventilation System Implemented in a Historical Church to Control Rising Damp
Type
Article in International Scientific Journal
Year
2013
Authors
João Delgado
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Ana Sofia Guimarães
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Vasco Peixoto De Freitas
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Journal
Title: Drying TechnologyImported from Authenticus Search for Journal Publications
Vol. 31
Pages: 385-392
ISSN: 0737-3937
Publisher: Taylor & Francis
Scientific classification
FOS: Engineering and technology > Civil engineering
CORDIS: Technological sciences
Other information
Authenticus ID: P-002-016
Abstract (EN): Treating rising damp in the walls of historic buildings is a very complex procedure and the traditional techniques currently used to minimize rising damp are not effective or too expensive, in particular when dealing with walls of considerable thickness and heterogeneous materials. This work presents the results of an in situ application of the hygro-regulated wall base ventilation system to control rising damp in a historical church located in northern Portugal. The main purpose is to validate the wall base ventilation technology for treating rising damp in very thick and heterogeneous walls. The analytical model used well describes the observed features of rising damp in building walls, verified by in-field tests, which contributed to simple sizing of the hygro-regulated wall base ventilation system to be implemented in historical buildings.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication with allowed access.
Related Publications

Of the same authors

Influence of Different Joints on Moisture Transport in Building Walls (2018)
Poster in an International Conference
Ana Sofia Guimarães; João M. P. Q. Delgado; Vasco Peixoto de Freitas; António Azevedo
Salt Damage and Rising Damp Treatment in Building Structures (2016)
Another Publication in an International Scientific Journal
Vasco Peixoto De Freitas; J.M.P.Q. Delgado; Ana Sofia Guimarães; Iñigo Antepara; Václav Kocí; Robert Cerný
Wall Base Ventilation Systems Design to the Treatment of Rising Damp (2012)
Book
Ana Sofia Guimarães; J. M. P. Q. Delgado; V. P. Freitas
Manual de apoio ao projecto de reabilitação de edifícios antigos (2012)
Book
Vasco Peixoto de Freitas; Ana Sofia Guimarães; Aníbal Costa; António Arêde ; A. P. Oliveira de Carvalho; Arlindo Begonha; Carlos Medeiros; Esmeralda Paupério; Eva Barreira; Helena Corvacho; Hipólito de Sousa; João Lopes Porto; João Miranda Guedes; Joaquim Teixeira; José Amorim Faria; Marisa Antunes Quintela; Nuno Ramos; Rui Fernandes Póvoas; Vasco Peixoto De Freitas
Hygrothermal Risk on Building Heritage: A Methodology for a Risk Map (2015)
Book
João M. P. Q. Delgado; Ana Sofia Guimarães; Vasco Peixoto de Freitas

See all (71)

Of the same scientific areas

E3.1 – Relatório: “Interfaces: Identificação e caracterização de necessidades/oportunidades de integração/interoperabilidade” (2021)
Technical Report
Hipólito Sousa; Joaquim Moreira; Jorge Teixeira; José Ferreira; Yanh Ribeiro
E1.1 – Relatório: “Síntese sobre os modelos de obra” (2021)
Technical Report
Hipólito Sousa; Joaquim Moreira; Jorge Teixeira; Pedro Mêda; Rui Miguel Sousa
Projecto de Estruturas de Madeira. (2009)
Book
João Negrão; José Amorim Faria

See all (72)

Of the same journal

The influence of microencapsulation with a modified chitosan (water soluble) on ß-galactosidase activity (2014)
Article in International Scientific Journal
Berta N. Estevinho; Ana M. Damas; Pedro Martins; Fernando Rocha
Shrinkage of apple disks during drying by warm air convection and freeze drying (2000)
Article in International Scientific Journal
R. Moreira; A. Figueiredo; Alberto Sereno
Project design abacus for wall base ventilation drying systems to control dampness (2016)
Article in International Scientific Journal
Ana Sofia Guimarães; Teixeira, M. J.
Microstructural changes during drying of apple slices (2005)
Article in International Scientific Journal
Mayor, L., Silva, M.A., Sereno, A.M.

See all (11)