Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > HEART-RATE-VARIABILITY IN 24-HOUR HOLTER RECORDINGS - COMPARATIVE-STUDY BETWEEN SHORT-TERM AND LONG-TERM TIME-DOMAIN AND FREQUENCY-DOMAIN ANALYSES

Publicações

HEART-RATE-VARIABILITY IN 24-HOUR HOLTER RECORDINGS - COMPARATIVE-STUDY BETWEEN SHORT-TERM AND LONG-TERM TIME-DOMAIN AND FREQUENCY-DOMAIN ANALYSES

Título
HEART-RATE-VARIABILITY IN 24-HOUR HOLTER RECORDINGS - COMPARATIVE-STUDY BETWEEN SHORT-TERM AND LONG-TERM TIME-DOMAIN AND FREQUENCY-DOMAIN ANALYSES
Tipo
Artigo em Revista Científica Internacional
Ano
1994
Autores
COSTA, O
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
LAGO, P
(Autor)
FCUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
ROCHA, AP
(Autor)
FCUP
CARVALHO, MJ
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
FREITAS, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
FREITAS, J
(Autor)
Outra
PUIG, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
BRANDAO, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
DEFREITAS, F
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 27
Páginas: 251-254
ISSN: 0022-0736
Editora: Elsevier
Classificação Científica
FOS: Ciências médicas e da saúde > Medicina clínica
Outras Informações
ID Authenticus: P-001-JX3
Abstract (EN): Mean hourly parameters obtained from all beats (long series) were compared with those obtained from a sample of 512 beats extracted each hour (short series) in nine presumably normal subjects. For both the short and long series, the spectral components, very low frequency, (VLF), low frequency (LF), and high frequency (HF), and time-domain indices (such as the Ewing statistic [PNN50] and RR standard deviation [SD-RR]), have been estimated. The spectral components LF and HF, estimated from the short and long series, were not significantly different, whereas significant differences were found between VLF, SD-RR, and PNN50. In both the short and long series, a strong correlation was found between LF and SD-RR and between HF and PNN50. The results suggest that, over a period of 24 hours, hourly LF and HF spectral components can be obtained using a single series of 512 beats every hour, with a great advantage over the evaluation of the mean hourly parameters. This method would be particularly useful in the study of circadian heart rate spectral analysis in Holter recordings with multiple artifacts or ectopic beats, and in general, when analysis of the entire 24-hour series is not feasible.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 4
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-25 às 11:59:13 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico