Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Firing distance estimation through the analysis of the gunshot residue deposit pattern around the bullet entrance hole by inductively coupled plasma-mass spectrometry - An experimental study

Publicações

Firing distance estimation through the analysis of the gunshot residue deposit pattern around the bullet entrance hole by inductively coupled plasma-mass spectrometry - An experimental study

Título
Firing distance estimation through the analysis of the gunshot residue deposit pattern around the bullet entrance hole by inductively coupled plasma-mass spectrometry - An experimental study
Tipo
Artigo em Revista Científica Internacional
Ano
2007
Autores
Agostinho Santos
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Teresa Magalhaes
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Duarte Nuno Vieira
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Antonio V Sousa
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Revista
Vol. 28 1
Páginas: 24-30
ISSN: 0195-7910
Classificação Científica
FOS: Ciências médicas e da saúde > Outras ciências médicas
Outras Informações
ID Authenticus: P-004-B8C
Abstract (EN): The use of inductively coupled plasma-mass spectrometry (ICP-MS) in the study of gunshot residues (GSR) is relatively recent, and only a few studies have been published on the subject. In the present paper, this instrumental technique has been used to study the deposit pattern of the GSR around the bullet entrance hole, through the analysis of antimony (Sb), barium (Ba), and lead (Pb). The data obtained were used to establish a mathematical model for estimating the firing distance. Test shots using a 6.35-mm pistol were made against a target of cotton tissue, and the amounts of Sb, Ba, and Pb deposited in quadrangular pieces of the target, cut from 4 radial positions, were determined by ICP-MS. In these experimental conditions, it was possible to estimate the firing distance on the interval [20-80] cm. The, best linear correlation between In m and d, where m is the mass of Sb, Ba, or Pb in the samples, expressed in mu g/g of target tissue, and d the firing distance, was obtained at radial distances between 3.5 cm and 4.5 cm from the entrance hole. The best regression curve which adjusted to the data was a linear multiple regression between the firing distance and the logarithm of the mass of each element: d = a + b(1)X(1) + b(2)X(2) + b(3)X(3), where X-1 = In m (Sb), X-2 = In m (Ba) and X-3 = In m (Pb). The accuracy of firing distance estimation using only 1 or 2 elements was not significantly different from the one obtained with the 3 elements.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Contacto: asantosinml@yahoo.com
Nº de páginas: 7
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-07-16 às 08:21:48 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias