Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Finite element analysis of the mechanical behavior of a partially edentulous mandible as a function of cancellous bone density.

Publicações

Finite element analysis of the mechanical behavior of a partially edentulous mandible as a function of cancellous bone density.

Título
Finite element analysis of the mechanical behavior of a partially edentulous mandible as a function of cancellous bone density.
Tipo
Artigo em Revista Científica Internacional
Ano
2009
Autores
Paulo Piloto
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Campos,J.Reis
(Autor)
FMDUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Mário Vaz
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Classificação Científica
FOS: Ciências médicas e da saúde > Ciências da saúde
CORDIS: Ciências da Saúde > Ciências Médicas > Medicina > Estomatologia ; Ciências Tecnológicas > Engenharia > Engenharia de biomateriais ; Ciências Tecnológicas > Engenharia > Engenharia mecânica
Outras Informações
Resumo (PT): Objetivo: Apresentar uma metodologia para modelamento geométrico de uma mandíbula humana e obtenção de um modelo discreto para simular numericamente o comportamento biomecânico de uma mandíbula parcialmente edêntula em função de diferentes densidades do osso trabecular. Metodologia: Utilizou-se o método de elementos finitos 3D para realizar um estudo numérico sobre um modelo de mandíbula humana, desdentada parcial tipo Classe I de Kennedy, com implantes nas regiões dos dentes 33 e 43. O modelo sólido geométrico foi determinado por tomografia computorizada e prototipagem. No modelo discretizado foi realizada uma análise paramétrica para verificar a influência da densidade óssea do osso trabecular (25%, 50%, 75%) no desenvolvimento de tensões e deformações da mandíbula durante a aplicação de forças mastigatórias na região anterior. Resultados: As tensões máximas de von Mises e deformações equivalentes no osso trabecular foram desenvolvidas próximo às regiões de aplicação das forças de mordida. Os picos de valores de tensões/deformações localizaram-se na região anterior da mandíbula, sendo que, para o mesmo valor de esforço de mordida, as tensões equivalentes aumentaram com a densidade óssea. Conclusão: Os resultados sugerem que as tensões e deformações desenvolvidas no modelo mandibular testado foram afetadas pelo grau de densidade do osso trabecular durante simulação de atividade mastigatória. Palavras-chave: Análise por elementos finitos; mandíbula; análise de tensões; comportamento mecânico; densidade óssea
Abstract (EN): Purpose: To present a methodological procedure to obtain the geometric and discrete models of a human mandible for numerical simulation of the biomechanical behavior of a partially edentulous mandible as a function of cancellous bone density. Methods: A 3D finite element method was used to assess the model of a partially edentulous mandible, Kennedy Class I, with dental implants placed at the region of teeth 33 and 43. The geometric solid model was built from CT-scan images and prototyping. In the discrete model a parametric analysis was performed to analyze the influence of cancellous bone density (25%, 50 %, 75 %) on the development of mandibular stress and strain during simulation of masticatory forces in the anterior region. Results: Maximum von Mises stress and equivalent strain values in cancellous bone were found close to the loading area (masticatory forces). The peak stress and strain values occurred in the mandibular anterior region, and for the same masticatory force the equivalent stresses increased with bone density. Conclusion: The results suggest that the stresses and strains developed in the mandibular model were affected by cancellous bone density during the simulation of masticatory activity. Key words: Finite element analysis; mandible; stress analysis; mechanical behavior; bone density.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Contacto: acorreia@fmd.up.pt
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Stress analysis of cantilever-fixed partial denture connector design using the finite element method. (2009)
Artigo em Revista Científica Internacional
A Correia; Sampaio-Fernandes J.; Campos,J.Reis; Mário Augusto Pires Vaz; Nuno Viriato Marques Ramos
Osteochondroma of the sigmoide notch: a case report of an unusual location (2016)
Artigo em Revista Científica Internacional
Ana Paula Reis Durão; Israel Chilvarquer; Márcia Provenzanoi; Teixeira Koch; Miranda M.; Aline Cantarelli Morosoll
In vitro study of the insertion and disinsertion effect on retention of two attachment systems of an overdenture on two implants (2014)
Artigo em Revista Científica Internacional
Elsa Carvalho; Maria Helena Figueiral; Patrícia Alexandra Barroso da Fonseca; Mário Vaz; Fernando Morais Branco
Evaluation of occlusal rest seat depth in bicuspids: an experimental study (2013)
Artigo em Revista Científica Internacional
José Reis Campos; André Correia; Maria Helena Figueiral; Patrícia Alexandra Barroso da Fonseca; Filomena Rodrigues; Fernando Morais Branco
CAD-CAM all-ceramic fully sintered zirconia crowns for the oral rehabilitation of an amelogenesis imperfecta case. (2009)
Artigo em Revista Científica Internacional
Sampaio-Fernandes J.; A Correia; Jorge André Cardoso; Pedro Ferrás da Silva Fernandes; Tiago Coutinho Almeida; Miguel Gonçalves Pinto
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-10-02 às 02:37:16 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico